Product Contents
Completing the Illumina 5-Base DNA Prep with Enrichment protocol requires library prep reagents, an Illumina Custom Enrichment Panel v2, and indexes. For Illumina Custom Enrichment Panel v2 information, refer to Illumina Custom Enrichment Panel v2 (Required).
|
Component |
Kit Options |
Catalog # |
|---|---|---|
|
Library prep reagents |
Illumina 5-Base DNA Prep with Enrichment, (24 samples) |
20140366 |
Reagent Kit Contents
The following tables list the contents of each box
|
Quantity |
Reagent |
Description |
|---|---|---|
|
1 |
ATL4 |
A-Tailing Mix |
|
1 |
DDR |
DNA Denaturation Reagent |
|
1 |
ERP6 |
End Repair Mix |
|
1 |
GDMC |
Genomic DNA Methylation Control |
|
1 |
IME |
Illumina Methylation Enzyme |
|
1 |
LIGX |
DNA Ligase X |
|
1 |
MAM |
Methylation Amplification Mix |
|
1 |
MCB |
Methylation Conversion Buffer |
|
1 |
MRR |
Methylation Resuspension Reagent |
|
1 |
SFMC |
Short Fragment Methylation Control |
|
1 |
UMI3 |
Unique Molecular Identifier |
|
Quantity |
Reagent |
Description |
|---|---|---|
|
1 |
IPB |
Illumina Purification Beads |
|
1 |
RSB |
Resuspension Buffer |
|
Quantity |
Reagent |
Description |
|---|---|---|
|
1 |
EEW |
Enhanced Enrichment Wash |
|
1 |
EPM4 |
Enhanced PCR Mix 4 |
|
1 |
NHB2 |
Hyb Buffer 2 + IDT NXT Blockers |
|
1 |
PPC |
PCR Primer Cocktail |
|
Quantity |
Reagent |
Description |
|---|---|---|
|
1 |
EHB2 |
Enrich Hyb Buffer 2 |
|
1 |
SMB4 |
Streptavidin Magnetic Beads 4 |
Use the required Illumina Custom Enrichment Panel v2 designed for Illumina 5-Base DNA Prep with Enrichment through Illumina DesignStudio.
| • | 75 kb–1 Mb panel size |
For more information about using DesignStudio to create Illumina custom enrichment panels, refer to the DesignStudio support page on the Illumina support website.
|
Description |
Number of Samples Supported |
|---|---|
|
Illumina Custom Enrichment Panel v2 |
Prepare up to 32 samples using 4-plex enrichment (32 μl, 120 bp) |
|
Prepare up to 384 samples using 4-plex enrichment (384 μl, 120 bp) |
|
|
Prepare up to 1536 samples using 4-plex enrichment (1536 μl, 120 bp) |
The [Optional] Methylation Control Panel provides methylation conversion quality control metrics. Use the [Optional] Methylation Control Panel with the required Illumina Custom Enrichment Panel v2. To prepare the [Optional] Methylation Control Panel for the protocol, refer to Prepare Reagents, and then Hybridize Probes.
The [Optional] Methylation Control Panel is available from DesignStudio. For more information, refer to the DesignStudio support page on the Illumina support website.
Select at least one set from the following options.
|
Component |
Description |
Catalog # |
|---|---|---|
|
Indexes |
Illumina Unique Dual Indexes LT (48 Indexes, 48 Samples) |
20098166 |
|
Illumina DNA/RNA UD Indexes Set A (96 Indexes, 96 Samples) |
20091654 |
|
|
Illumina DNA/RNA UD Indexes Set B (96 Indexes, 96 Samples) |
20091656 |
|
|
Illumina DNA/RNA UD Indexes Set C (96 Indexes, 96 Samples) |
20091658 |
|
|
Illumina DNA/RNA UD Indexes Set D (96 Indexes, 96 Samples) |
20091660 |