User-Supplied Consumables & Equipment
This snippet causes dropdowns to open on page load. This text/paragraph does not appear in the output.
Make sure that you have the required consumables and equipment before starting the protocol.
Some items are required only for specific workflows. These items are specified in separate tables.
The protocol has been optimized and validated using the items listed. Comparable performance is not guaranteed when using alternate consumables and equipment.
|
Consumable |
Supplier |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1.7 ml microcentrifuge tubes |
General lab supplier |
||||||||||||
|
10 µl pipette tips |
General lab supplier |
||||||||||||
|
20 µl pipette tips |
General lab supplier |
||||||||||||
|
200 µl pipette tips |
General lab supplier |
||||||||||||
|
1000 µl pipette tips |
General lab supplier |
||||||||||||
|
96-well 0.8 ml polypropylene deep-well storage plate (MIDI plate) |
Thermo Fisher Scientific, part # AB-0859 |
||||||||||||
|
Nuclease-free water |
General lab supplier |
||||||||||||
|
Hard-Shell 96-well PCR plates |
Bio-Rad, catalog # HSP-9601 |
||||||||||||
|
Microseal 'B' adhesive seals |
Bio-Rad, catalog # MSB-1001 |
||||||||||||
|
Microseal 'F' foil seals |
Bio-Rad, catalog # MSF-1001 |
||||||||||||
|
RNase/DNase-free multichannel reagent reservoirs, disposable |
VWR [Optional] catalog # 89094-658 |
||||||||||||
|
Ethanol 200 proof (absolute) for molecular biology (500 ml) |
Sigma-Aldrich, product # E7023 |
||||||||||||
|
Qubit dsDNA HS Assay Kit |
One of the following, depending on quantification method:
|
||||||||||||
|
Quant-iT PicoGreen dsDNA Assay Kit |
Thermo Fisher Scientific, catalog # P11496 |
||||||||||||
|
Qubit Assay Tubes |
Thermo Fisher Scientific, catalog # Q32856 |
||||||||||||
|
One of the following kits for quantification:
|
|
||||||||||||
|
One of the following kits, depending on qualification method: |
Agilent Technologies, catalog #: |
||||||||||||
|
[Fragment Analyzer] High Sensitivity NGS Fragment Analysis Kit |
DNF-474-0500 |
||||||||||||
|
[Bioanalyzer] Agilent High Sensitivity DNA Kit |
5067–4626* |
||||||||||||
|
[Dried Blood]Dried Blood Spots (DBS) card |
GE Healthcare, catalog # 10534320 |
||||||||||||
|
[Blood] EDTA blood collection tubes |
Becton Dickinson |
||||||||||||
|
[Saliva] Oragene DNA collection kit for saliva |
Genotek, catalog # OGR-500 or OGD-510 |
* End of life announced. Refer to vendor site for more information.
Consumables for Blood, Saliva, and Dried Blood Spot Input
|
Consumable |
Supplier |
|---|---|
|
[Dried Blood]Dried Blood Spots (DBS) card |
GE Healthcare, catalog # 10534320 |
|
[Blood] Flex Lysis Reagent Kit |
Illumina, catalog # 20018706 |
|
[Blood] EDTA blood collection tubes |
Becton Dickinson |
|
[Saliva] Oragene DNA collection kit for saliva |
Genotek, catalog # OGR-500 or OGD-510 |
|
Equipment |
Supplier |
||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
10 µl multichannel pipette |
General lab supplier |
||||||||||||||||||||||||
|
10 µl single channel pipette |
General lab supplier |
||||||||||||||||||||||||
|
20 µl multichannel pipette |
General lab supplier |
||||||||||||||||||||||||
|
20 µl single channel pipette |
General lab supplier |
||||||||||||||||||||||||
|
200 µl multichannel pipette |
General lab supplier |
||||||||||||||||||||||||
|
200 µl single channel pipette |
General lab supplier |
||||||||||||||||||||||||
|
1000 µl single channel pipette |
General lab supplier |
||||||||||||||||||||||||
|
Magnetic Stand-96 |
Thermo Fisher Scientific, catalog # AM 10027 |
||||||||||||||||||||||||
|
Microplate centrifuge |
General lab supplier |
||||||||||||||||||||||||
|
Microcentrifuge |
General lab supplier |
||||||||||||||||||||||||
|
Qubit Fluorometer 4.0 |
Thermo Fisher Scientific, catalog # Q33238 or Q33327 |
||||||||||||||||||||||||
|
Vortexer |
General lab supplier |
||||||||||||||||||||||||
|
One of the following analyzers:
|
Agilent Technologies catalog #:
|
||||||||||||||||||||||||
|
[Saliva] Water bath or air incubator capable of reaching 50°C |
As recommended by DNA Genotek, refer to product pages. |
* No longer available for purchase.
The following table lists the recommended settings for the thermal cycler. If your lab has a thermal cycler that is not listed, validate the thermal cycler before performing the protocol.
|
Thermal Cycler |
Supplier/Description |
||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
C1000 Touch Thermal Cycler with 96–Deep Well Reaction Module, separate |
Bio-Rad part # 1851197¹ |
||||||||||||||||||||||||
|
Bio-Rad DNA Engine Tetrad 2 |
Bio-Rad part # PTC-0240G² |
||||||||||||||||||||||||
|
Thermal cycler with the following specifications:
|
General lab supplier |
||||||||||||||||||||||||
|
MJ Research DNA Engine Tetrad |
MJ Research part # MJ-T2-4 |
||||||||||||||||||||||||
|
Eppendorf Mastercycler Pro S (Gradient S, Simulated Tube) |
Eppendorf part # 41102404 |
¹ End of life announced. Refer to vendor site for more information.
² No longer available for purchase.