Product Contents
This snippet causes dropdowns to open on page load. This text/paragraph does not appear in the output.
Make sure that you have all reagents identified in this section before starting library prep. The protocol requires one Illumina RNA Prep with Enrichment, (L) Tagmentation kit, one panel, and at least one Illumina DNA/RNA UD Indexes set. Combine all four index adapter sets to index 384 libraries.
| • | The required library preparation kits provide reagents for denaturing, cDNA synthesis, library prep, and enrichment in a 16-sample 1-plex workflow, or 96-sample 3-plex workflow. |
| • | The enrichment panels provide application-specific oligos. |
| • | The index sets provide premixed Index 1 (i7) and Index 2 (i5) adapters. |
Illumina Purification Beads (IPB) are also required. These reagents are not included in the Illumina kits and must be purchased separately. Refer to User-Supplied Consumables and Equipment for the IPB quantity requirements and catalog numbers.
|
Component |
Name |
Catalog # |
|---|---|---|
|
Library prep reagents |
Illumina RNA Prep with Enrichment, (L) Tagmentation (16 samples)¹ |
20040536 |
|
Illumina RNA Prep with Enrichment, (L) Tagmentation (96 samples)² |
20040537 |
|
|
Index adapters |
Illumina DNA/RNA UD Indexes Set A, Tagmentation (96 indexes, 96 samples) |
20091654 |
|
Illumina DNA/RNA UD Indexes Set B, Tagmentation (96 indexes, 96 samples) |
20091656 |
|
|
Illumina DNA/RNA UD Indexes Set C, Tagmentation (96 indexes, 96 samples) |
20091658 |
|
|
Illumina DNA/RNA UD Indexes Set D, Tagmentation (96 indexes, 96 samples) |
20091660 |
|
|
Enrichment Panels |
Respiratory Virus Oligo Panel v2 |
20044311 |
|
Illumina Exome Panel (CEX) |
20020183 |
|
|
Pan-Coronavirus Panel |
20088155 |
|
|
Respiratory Virus Enrichment Kit Set A (96 samples) |
20100469 |
|
|
Respiratory Virus Enrichment Kit Set B (96 samples) |
20100470 |
|
|
Respiratory Virus Enrichment Kit Set C (96 samples) |
20100471 |
|
|
Respiratory Virus Enrichment Kit Set D (96 samples) |
20100472 |
|
|
Illumina Custom Enrichment Panel v2 (32 µl, 120 bp) |
20073953 |
|
|
Illumina Custom Enrichment Panel v2 (384 µl, 120 bp) |
20073952 |
|
|
Illumina Custom Enrichment Panel v2 (1536 µl, 120 bp) |
20111339 |
|
|
Respiratory Pathogen ID/AMR Enrichment Kit |
Respiratory Pathogen ID/AMR Oligo Enrichment Kit (RUO) A |
20047050 |
|
Respiratory Pathogen ID/AMR Oligo Enrichment Kit (RUO) B |
20046969 |
|
|
Respiratory Pathogen ID/AMR Oligo Enrichment Kit (RUO) C |
20047051 |
|
|
Respiratory Pathogen ID/AMR Oligo Enrichment Kit (RUO) D |
20047052 |
¹Kit includes reagents for 16 one-plex enrichment reactions.
²Kit includes reagents for 32 three-plex enrichment reactions.
Reagent Kit Contents
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
1 |
4 |
EPH3 |
Elute, Prime, Fragment High Concentration Mix |
|
1 |
4 |
FSA |
First Strand Synthesis Act D Mix |
|
1 |
2 |
RSB |
Resuspension Buffer This RSB is stored frozen. |
|
1 |
1 |
RVT |
Reverse Transcriptase |
|
1 |
4 |
SMM |
Second Strand Marking Master Mix |
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
2 |
4 |
EPM |
Enhanced PCR Mix |
|
1 |
4 |
TB1 |
Tagmentation Buffer 1 |
*Shipped at 2°C to 8°C. Promptly store at the indicated temperature to ensure proper performance.
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
1 |
2 |
EE1 |
Enrichment Elution Buffer 1 |
|
1 |
4 |
EEW |
Enhanced Enrichment Wash |
|
1 |
2 |
EPM |
Enhanced PCR Mix |
|
1 |
1 |
HP3 |
2 N NaOH |
|
1 |
1 |
NHB2 |
Hyb Buffer 2+IDT NXT Blockers |
|
1 |
1 |
PPC |
PCR Primer Cocktail |
*Shipped at 2°C to 8°C. Promptly store at the indicated temperature to ensure proper performance.
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
1 |
4 |
EBLTL |
Enrichment Bead-Linked Transposomes |
|
1 |
2 |
RSB |
Resuspension Buffer* |
*Promptly store at the indicated temperature to ensure proper performance.
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
1 |
1 |
EHB2 |
Enrich Hyb Buffer 2 |
|
1 |
1 |
ET2 |
Elute Target Buffer 2 |
|
1 |
1 |
RSB |
Resuspension Buffer* This RSB is stored cold. |
|
1 |
2 |
SMB4 |
Streptavidin Magnetic Beads 4 |
*Promptly store at the indicated temperature to ensure proper performance.
|
Tube Quantity |
Reagent |
Description |
|
|---|---|---|---|
|
16 Samples |
96 Samples |
||
|
1 |
4 |
ST2 |
Stop Tagment Buffer 2 |
|
1 |
1 |
TWB |
Tagmentation Wash Buffer |
*Shipped at 2°C to 8°C. Promptly store at the indicated temperature to ensure proper performance.
Index Adapters and Enrichment Panels
|
Quantity |
Reagent |
Description |
|---|---|---|
|
1 |
UDP0001–UDP0096 |
Set A index adapter plate |
|
1 |
UDP0097–UDP0192 |
Set B index adapter plate |
|
1 |
UDP0193V3–UDP0288V3 |
Set C index adapter plate |
|
1 |
UDP0289V2–UDP0384 |
Set D index adapter plate |
|
Panel Name |
Quantity |
Reagent |
Description |
|---|---|---|---|
|
Illumina Exome Panel |
1 |
CEX |
Coding Exome Oligos |
|
Pan-Coronavirus Panel |
1 |
Pan-CoV |
Pan-Coronavirus Oligos |
|
Illumina Custom Enrichment Panel v2 |
1 |
ICEPv2 |
Custom Panel Oligos |
|
Respiratory Virus Oligo Panel v2 |
1 |
RVOPv2 |
Respiratory Virus Oligos |
|
Respiratory Pathogen ID/AMR Oligo |
1 |
RPIP |
Respiratory Pathogen ID/AMR Oligos |