Illumina-Supplied Consumables
Completing the Nextera XT protocol requires library prep reagents and index adapters.
|
Component |
Kit Options |
Catalog # |
|---|---|---|
|
Library prep reagents |
Nextera XT DNA Library Preparation Kit (24 Samples) |
FC-131-1024 |
|
Nextera XT DNA Library Preparation Kit (96 Samples) |
FC-131-1096 |
|
|
Index adapters |
IDT for Illumina DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples) |
20027213 |
|
IDT for Illumina DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples) |
20027214 |
|
|
IDT for Illumina DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples) |
20042666 |
|
|
IDT for Illumina DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples) |
20042667 |
|
|
IDT for Illumina Nextera DNA Unique Dual Indexes Set C (96 Indexes, 96 Samples) |
20027215 |
|
|
IDT for Illumina Nextera DNA Unique Dual Indexes Set D (96 Indexes, 96 Samples) |
20027216 |
|
|
Nextera XT Index Kit v2 Set A (96 Indexes, 384 Samples) |
FC-131-2001 |
|
|
Nextera XT Index Kit v2 Set B (96 Indexes, 384 Samples) |
FC-131-2002 |
|
|
Nextera XT Index Kit v2 Set C (96 Indexes, 384 Samples) |
FC-131-2003 |
|
|
Nextera XT Index Kit v2 Set D (96 Indexes, 384 Samples) |
FC-131-2004 |
|
|
Nextera XT Index Kit (24 Indexes, 96 Samples) |
FC-131-1001 |
|
|
Accessory Products for Nextera XT |
Illumina Purification Bead, 100 ml |
20060057 |
|
Illumina Purification Bead, 400 ml |
20060058 |
Box 1 of 2
These reagents are shipped at -25°C to -15°C. Promptly store reagents at the indicated tube temperature to ensure proper performance.
|
Tube Quantity |
Acronym |
Reagent Name |
Storage Temperature |
|
|---|---|---|---|---|
|
24 Samples |
96 Samples |
|||
|
1 |
1 |
ATM |
Amplicon Tagment Mix |
-25°C to -15°C |
|
1 |
2 |
TD |
Tagment DNA Buffer |
-25°C to -15°C |
|
1 |
1 |
NPM |
Nextera PCR Master Mix |
-25°C to -15°C |
|
1 |
4 |
RSB |
Resuspension Buffer |
-25°C to -15°C |
|
1 |
1 |
LNA1 |
Library Normalization Additives 1 |
-25°C to -15°C |
|
1 |
2 |
LNW1 |
Library Normalization Wash 1 |
2°C to 8°C |
Box 2 of 2
These reagents are shipped at -25°C to -15°C. Promptly store reagents at the indicated tube temperature to ensure proper performance.
|
Tube Quantity |
Acronym |
Reagent Name |
Storage Temperature |
|
|---|---|---|---|---|
|
24 Samples |
96 Samples |
|||
|
1 |
1 |
NT |
Neutralize Tagment Buffer |
Room temperature |
|
1 |
1 |
LNB1 |
Library Normalization Beads 1 |
2°C to 8°C |
|
1 |
1 |
LNS1 |
Library Normalization Storage Buffer 1 |
Room temperature |
For index adapter sequences, refer to Illumina Adapter Sequences.
IDT for Illumina Nextera DNA UD Indexes (96 Indexes, 96 Samples) Plate Format, Store at -25°C to -15°C
|
Quantity |
Description |
|---|---|
|
1 |
96 Dual Adapter Index Plate |
Nextera XT Index Kit v2 (96 indexes, 384 Samples), Store at -25°C to -15°C
|
Set |
Quantity |
Description |
|---|---|---|
|
A |
8 tubes |
Index Primers, S502, S503, S505–S508, S510, and S511 |
|
12 tubes |
Index Primers, N701–N707, N710–N712, N714, and N715 |
|
|
B |
8 tubes |
Index Adapters: S502, S503, S505–S508, S510, and S511 |
|
12 tubes |
Index Adapters: N716, N718–N724, and N726–N729 |
|
|
C |
8 tubes |
Index Adapters: S513, S515–S518, and S520–S522 |
|
12 tubes |
Index Adapters: N701–N707, N710–N712, N714, and N715 |
|
|
D |
8 tubes |
Index Adapters: S513, S515–S518, and S520–S522 |
|
12 tubes |
Index Adapters: N716, N718–N724, and N726–N729 |
Index Adapter Replacement Caps, Store at 15°C to 30°C
|
Quantity |
Description |
|---|---|
|
1 bag |
i7 Index Tube Caps, Orange |
|
1 bag |
i5 Index Tube Caps, White |
Nextera XT Index Kit (24 Indexes, 96 Samples), Store at -25°C to -15°C
|
Quantity |
Description |
|---|---|
|
4 tubes |
Index Adapters: S502–S504 and S517 |
|
6 tubes |
Index Adapters: N701–N706 |
Index Adapter Replacement Caps, Store at 15°C to 30°C
|
Quantity |
Description |
|---|---|
|
1 bag |
i7 Index Tube Caps, Orange |
|
1 bag |
i5 Index Tube Caps, White |
TruSeq Index Plate Fixture Kit, Store at Room Temperature (Optional)
Each TruSeq Index Plate Fixture Kit contains two fixtures to help arrange index primers before dispensing to a 96-well plate during library amplification. The fixture pairs with both the 24-sample kit and 96-sample kit.
|
Quantity |
Description |
|---|---|
|
2 |
TruSeq Index Plate Fixture |