User-Supplied Consumables & Equipment
The following sections provide information on the required user-supplied consumables and equipment.
The specific brands of plastic consumables have been validated for stability of PIP emulsions. Substituting these materials can adversely affect performance.
|
Consumable |
Supplier |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0.2 ml PCR 8-tube strips and caps, emulsion safe |
One of the following suppliers:
|
|||||||||||||||||||||
|
0.5 ml Safe-Lock PCR Clean tubes, emulsion safe |
One of the following suppliers:
|
|||||||||||||||||||||
|
1.5 ml Safe-Lock PCR Clean tubes, emulsion safe |
One of the following suppliers:
|
|||||||||||||||||||||
|
[Fresh cells] 5 ml polypropylene centrifuge tubes, sterile |
Fisher Scientific, catalog # 13-864-407 |
|||||||||||||||||||||
|
[Cryopreserved cells] 15 ml polypropylene centrifuge tubes, sterile |
Corning, catalog # 430790 or general lab supplier |
|||||||||||||||||||||
|
Absolute ethanol, molecular biology grade |
General lab supplier |
|||||||||||||||||||||
|
[Isolated nuclei input] BSA, molecular biology grade |
General lab supplier |
|||||||||||||||||||||
|
Cell counting materials (eg, AO/PI) |
General lab supplier |
|||||||||||||||||||||
|
Nuclease-free water |
Thermo Fisher, catalog # AM9937 or general lab supplier |
|||||||||||||||||||||
|
Nuclease-free 1X low EDTA TE Buffer (IDTE), pH 8.0, 10 mM Tris, 0.1 mM EDTA |
IDT, catalog # 11-05-01-09 or general lab supplier |
|||||||||||||||||||||
|
Pipette tips, filtered, low retention, sterilized, 20 μl |
One of the following suppliers:
|
|||||||||||||||||||||
|
Pipette tips, filtered, low retention, sterilized, 200 μl |
One of the following suppliers:
|
|||||||||||||||||||||
|
Pipette tips, filtered, low retention, sterilized, 1000 μl |
One of the following suppliers:
|
|||||||||||||||||||||
|
Pipette tips, wide bore, filtered, low retention, sterilized, 200 μl |
Rainin, catalog # 30389241 |
|||||||||||||||||||||
|
Pipette tips, wide bore, filtered, low retention, sterilized, 1000 μl |
Rainin, catalog # 30389218 |
|||||||||||||||||||||
|
PCR tube strips and caps, or PCR reaction plates (if you have a compatible magnetic bead rack) |
General lab supplier |
|||||||||||||||||||||
|
Quantification consumables, depending on system:
|
One of the following suppliers, depending on system:
|
|||||||||||||||||||||
|
Qubit 1X dsDNA High Sensitivity Assay Kit |
Thermo Fisher, catalog # Q33230 or Q33231 |
|||||||||||||||||||||
|
Qubit Assay Tubes |
Thermo Fisher, catalog # Q32856 |
|||||||||||||||||||||
|
[Isolated nuclei input] RNase Inhibitor |
One of the following suppliers:
|
|||||||||||||||||||||
|
[Optional] Cell Strainers |
General lab supplier |
|
Equipment |
Supplier |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0.2 ml/1.5 ml Magnetic Separation Combo Rack |
Permagen, MSR1224B or equivalent from alternative supplier |
||||||||||||
|
Benchtop centrifuge with swinging bucket rotor, suitable for 5/15 ml tubes |
General lab supplier, recommend Thermo Scientific ST40 |
||||||||||||
|
Benchtop mini microcentrifuge 2000 × g, suitable for 0.5/1.5 ml tubes and PCR tube strips. |
Thermo Fisher, catalog # 75004061 or general lab supplier |
||||||||||||
|
[Optional] Dry bath* The following components must be ordered separately:
|
Eppendorf, catalog # 5383000027
Eppendorf, catalog # 5308000003 Eppendorf, catalog # 5361000031 |
||||||||||||
|
Hemocytometer or automated cell counter |
General lab supplier |
||||||||||||
|
Ice bucket or cold blocks, suitable for 0.2/0.5 ml PCR tubes and 1.5 ml microcentrifuge tubes |
General lab supplier |
||||||||||||
|
Micropipettes, 1–1000 µl capabilities (Rainin LTS-tip compatible pipettes are required if you are using the recommended Rainin pipette tips) |
General lab supplier |
||||||||||||
|
Quantification system, either of the following:
|
One of the following suppliers, depending on system:
|
||||||||||||
|
Qubit Fluorometer |
Thermo Fisher |
||||||||||||
|
Thermal cycler |
General lab supplier |
||||||||||||
|
Vortexer |
General lab supplier |
*The dry bath and its associated components are only required if you purchased the Illumina Single Cell Vortexer and Accessories starter equipment kit.
