Illumina Single Cell RNA Indexes
Do not use quality trimming or adapter trimming when converting BCL files into FASTQ files. When using a sample sheet, make sure that no adapter reads are listed under Adapter, Adapter Read 1, or Adapter Read 2.
Refer to Index 2 (i5) Orientation for more information on how to enter i5 bases on the sample sheet in forward or reverse complement orientation.
|
Index Name |
i7 Bases in Adapter |
i7 Bases for Sample Sheet |
i5 Bases in Adapter |
i5 Bases for Sample Sheet in Forward Orientation |
i5 Bases for Sample Sheet in Reverse Complement Orientation |
|---|---|---|---|---|---|
|
SCUDP0001 |
CGCTCAGTTC |
GAACTGAGCG |
TCGTGGAGCG |
TCGTGGAGCG |
CGCTCCACGA |
|
SCUDP0002 |
TATCTGACCT |
AGGTCAGATA |
CTACAAGATA |
CTACAAGATA |
TATCTTGTAG |
|
SCUDP0003V3 |
TCGGATGTCG |
CGACATCCGA |
TACGTTCATT |
TACGTTCATT |
AATGAACGTA |
|
SCUDP0004 |
CTTATGGAAT |
ATTCCATAAG |
TGCCTGGTGG |
TGCCTGGTGG |
CCACCAGGCA |
|
SCUDP0005V3 |
TCCTATTGTG |
CACAATAGGA |
TCCATCCGAG |
TCCATCCGAG |
CTCGGATGGA |
|
SCUDP0006 |
GCGCGATGTT |
AACATCGCGC |
GTCCACTTGT |
GTCCACTTGT |
ACAAGTGGAC |
|
SCUDP0007 |
AGAGCACTAG |
CTAGTGCTCT |
TGGAACAGTA |
TGGAACAGTA |
TACTGTTCCA |
|
SCUDP0008 |
TGCCTTGATC |
GATCAAGGCA |
CCTTGTTAAT |
CCTTGTTAAT |
ATTAACAAGG |
|
SCUDP0009 |
CTACTCAGTC |
GACTGAGTAG |
GTTGATAGTG |
GTTGATAGTG |
CACTATCAAC |
|
SCUDP0010 |
TCGTCTGACT |
AGTCAGACGA |
ACCAGCGACA |
ACCAGCGACA |
TGTCGCTGGT |
|
SCUDP0011 |
GAACATACGG |
CCGTATGTTC |
CATACACTGT |
CATACACTGT |
ACAGTGTATG |
|
SCUDP0012 |
CCTATGACTC |
GAGTCATAGG |
GTGTGGCGCT |
GTGTGGCGCT |
AGCGCCACAC |
|
SCUDP0013 |
TAATGGCAAG |
CTTGCCATTA |
ATCACGAAGG |
ATCACGAAGG |
CCTTCGTGAT |
|
SCUDP0014 |
GTGCCGCTTC |
GAAGCGGCAC |
CGGCTCTACT |
CGGCTCTACT |
AGTAGAGCCG |
|
SCUDP0015 |
CGGCAATGGA |
TCCATTGCCG |
GAATGCACGA |
GAATGCACGA |
TCGTGCATTC |
|
SCUDP0016 |
GCCGTAACCG |
CGGTTACGGC |
AAGACTATAG |
AAGACTATAG |
CTATAGTCTT |
|
SCUDP0017 |
AACCATTCTC |
GAGAATGGTT |
TCGGCAGCAA |
TCGGCAGCAA |
TTGCTGCCGA |
|
SCUDP0018 |
GGTTGCCTCT |
AGAGGCAACC |
CTAATGATGG |
CTAATGATGG |
CCATCATTAG |
|
SCUDP0019 |
CTAATGATGG |
CCATCATTAG |
GGTTGCCTCT |
GGTTGCCTCT |
AGAGGCAACC |
|
SCUDP0020 |
TCGGCCTATC |
GATAGGCCGA |
CGCACATGGC |
CGCACATGGC |
GCCATGTGCG |
|
SCUDP0021 |
AGTCAACCAT |
ATGGTTGACT |
GGCCTGTCCT |
GGCCTGTCCT |
AGGACAGGCC |
|
SCUDP0022 |
GAGCGCAATA |
TATTGCGCTC |
CTGTGTTAGG |
CTGTGTTAGG |
CCTAACACAG |
|
SCUDP0023 |
AACAAGGCGT |
ACGCCTTGTT |
TAAGGAACGT |
TAAGGAACGT |
ACGTTCCTTA |
|
SCUDP0024 |
GTATGTAGAA |
TTCTACATAC |
CTAACTGTAA |
CTAACTGTAA |
TTACAGTTAG |
|
SCUDP0025 |
TTCTATGGTT |
AACCATAGAA |
GGCGAGATGG |
GGCGAGATGG |
CCATCTCGCC |
|
SCUDP0026 |
CCTCGCAACC |
GGTTGCGAGG |
AATAGAGCAA |
AATAGAGCAA |
TTGCTCTATT |
|
SCUDP0027 |
TGGATGCTTA |
TAAGCATCCA |
TCAATCCATT |
TCAATCCATT |
AATGGATTGA |
|
SCUDP0028 |
ATGTCGTGGT |
ACCACGACAT |
TCGTATGCGG |
TCGTATGCGG |
CCGCATACGA |
|
SCUDP0029 |
AGAGTGCGGC |
GCCGCACTCT |
TCCGACCTCG |
TCCGACCTCG |
CGAGGTCGGA |
|
SCUDP0030 |
TGCCTGGTGG |
CCACCAGGCA |
CTTATGGAAT |
CTTATGGAAT |
ATTCCATAAG |
|
SCUDP0031 |
TGCGTGTCAC |
GTGACACGCA |
GCTTACGGAC |
GCTTACGGAC |
GTCCGTAAGC |
|
SCUDP0032 |
CATACACTGT |
ACAGTGTATG |
GAACATACGG |
GAACATACGG |
CCGTATGTTC |
|
SCUDP0033 |
CGTATAATCA |
TGATTATACG |
GTCGATTACA |
GTCGATTACA |
TGTAATCGAC |
|
SCUDP0034 |
TACGCGGCTG |
CAGCCGCGTA |
ACTAGCCGTG |
ACTAGCCGTG |
CACGGCTAGT |
|
SCUDP0035 |
GCGAGTTACC |
GGTAACTCGC |
AAGTTGGTGA |
AAGTTGGTGA |
TCACCAACTT |
|
SCUDP0036 |
TACGGCCGGT |
ACCGGCCGTA |
TGGCAATATT |
TGGCAATATT |
AATATTGCCA |
|
SCUDP0037 |
GTCGATTACA |
TGTAATCGAC |
GATCACCGCG |
GATCACCGCG |
CGCGGTGATC |
|
SCUDP0038 |
CTGTCTGCAC |
GTGCAGACAG |
TACCATCCGT |
TACCATCCGT |
ACGGATGGTA |
|
SCUDP0039 |
CAGCCGATTG |
CAATCGGCTG |
GCTGTAGGAA |
GCTGTAGGAA |
TTCCTACAGC |
|
SCUDP0040 |
TGACTACATA |
TATGTAGTCA |
CGCACTAATG |
CGCACTAATG |
CATTAGTGCG |
|
SCUDP0041 |
ATTGCCGAGT |
ACTCGGCAAT |
GACAACTGAA |
GACAACTGAA |
TTCAGTTGTC |
|
SCUDP0042 |
GCCATTAGAC |
GTCTAATGGC |
AGTGGTCAGG |
AGTGGTCAGG |
CCTGACCACT |
|
SCUDP0043 |
GGCGAGATGG |
CCATCTCGCC |
TTCTATGGTT |
TTCTATGGTT |
AACCATAGAA |
|
SCUDP0044 |
TGGCTCGCAG |
CTGCGAGCCA |
AATCCGGCCA |
AATCCGGCCA |
TGGCCGGATT |
|
SCUDP0045 |
TAGAATAACG |
CGTTATTCTA |
CCATAAGGTT |
CCATAAGGTT |
AACCTTATGG |
|
SCUDP0046V3 |
TCCATGTTGC |
GCAACATGGA |
CTTGTCTTAA |
CTTGTCTTAA |
TTAAGACAAG |
|
SCUDP0047 |
TATCCAGGAC |
GTCCTGGATA |
CGGTGGCGAA |
CGGTGGCGAA |
TTCGCCACCG |
|
SCUDP0048 |
AGTGCCACTG |
CAGTGGCACT |
TAACAATAGG |
TAACAATAGG |
CCTATTGTTA |
|
SCUDP0049 |
GTGCAACACT |
AGTGTTGCAC |
CTGGTACACG |
CTGGTACACG |
CGTGTACCAG |
|
SCUDP0050 |
ACATGGTGTC |
GACACCATGT |
TCAACGTGTA |
TCAACGTGTA |
TACACGTTGA |
|
SCUDP0051 |
GACAGACAGG |
CCTGTCTGTC |
ACTGTTGTGA |
ACTGTTGTGA |
TCACAACAGT |
|
SCUDP0052 |
TCTTACATCA |
TGATGTAAGA |
GTGCGTCCTT |
GTGCGTCCTT |
AAGGACGCAC |
|
SCUDP0053V3 |
TACCGAACTA |
TAGTTCGGTA |
CCATGTGTAG |
CCATGTGTAG |
CTACACATGG |
|
SCUDP0054V3 |
GTAGTAATAG |
CTATTACTAC |
GAGTCTCTCC |
GAGTCTCTCC |
GGAGAGACTC |
|
SCUDP0055V3 |
GGTTATGCTA |
TAGCATAACC |
GCTATGCGCA |
GCTATGCGCA |
TGCGCATAGC |
|
SCUDP0056V3 |
ACAATAGAGT |
ACTCTATTGT |
ATCGCATATG |
ATCGCATATG |
CATATGCGAT |
|
SCUDP0057 |
TTAGGATAGA |
TCTATCCTAA |
CGTCGACTGG |
CGTCGACTGG |
CCAGTCGACG |
|
SCUDP0058 |
CCGAAGCGAG |
CTCGCTTCGG |
TACTAGTCAA |
TACTAGTCAA |
TTGACTAGTA |
|
SCUDP0059 |
GGACCAACAG |
CTGTTGGTCC |
ATAGACCGTT |
ATAGACCGTT |
AACGGTCTAT |
|
SCUDP0060 |
TTCCAGGTAA |
TTACCTGGAA |
ACAGTTCCAG |
ACAGTTCCAG |
CTGGAACTGT |
|
SCUDP0061 |
TGATTAGCCA |
TGGCTAATCA |
AGGCATGTAG |
AGGCATGTAG |
CTACATGCCT |
|
SCUDP0062 |
TAACAGTGTT |
AACACTGTTA |
GCAAGTCTCA |
GCAAGTCTCA |
TGAGACTTGC |
|
SCUDP0063 |
ACCGCGCAAT |
ATTGCGCGGT |
TTGGCTCCGC |
TTGGCTCCGC |
GCGGAGCCAA |
|
SCUDP0064 |
GTTCGCGCCA |
TGGCGCGAAC |
AACTGATACT |
AACTGATACT |
AGTATCAGTT |
|
SCUDP0065 |
AGACACATTA |
TAATGTGTCT |
GTAAGGCATA |
GTAAGGCATA |
TATGCCTTAC |
|
SCUDP0066 |
GCGTTGGTAT |
ATACCAACGC |
AATTGCTGCG |
AATTGCTGCG |
CGCAGCAATT |
|
SCUDP0067 |
AGCACATCCT |
AGGATGTGCT |
TTACAATTCC |
TTACAATTCC |
GGAATTGTAA |
|
SCUDP0068 |
TTGTTCCGTG |
CACGGAACAA |
AACCTAGCAC |
AACCTAGCAC |
GTGCTAGGTT |
|
SCUDP0069V3 |
AAGGCCTTGG |
CCAAGGCCTT |
TCGAAGTACT |
TCGAAGTACT |
AGTACTTCGA |
|
SCUDP0070V3 |
TGTGGAGTAA |
TTACTCCACA |
GACACCGATG |
GACACCGATG |
CATCGGTGTC |
|
SCUDP0071V3 |
CACTTCTACT |
AGTAGAAGTG |
CTAGCGTCGA |
CTAGCGTCGA |
TCGACGCTAG |
|
SCUDP0072V3 |
TGGACTCGTA |
TACGAGTCCA |
TAGCGAAGCA |
TAGCGAAGCA |
TGCTTCGCTA |
|
SCUDP0073V3 |
TATCATGAGA |
TCTCATGATA |
AACACGTGGA |
AACACGTGGA |
TCCACGTGTT |
|
SCUDP0074V3 |
CTTGGCCTCG |
CGAGGCCAAG |
GTGTTACCGG |
GTGTTACCGG |
CCGGTAACAC |
|
SCUDP0075V3 |
GTCTCGTGAA |
TTCACGAGAC |
AGATTGTTAC |
AGATTGTTAC |
GTAACAATCT |
|
SCUDP0076V3 |
CCATCCACGC |
GCGTGGATGG |
TTGACCAATG |
TTGACCAATG |
CATTGGTCAA |
|
SCUDP0077 |
GGATACCAGA |
TCTGGTATCC |
CGTTGCTTAC |
CGTTGCTTAC |
GTAAGCAACG |
|
SCUDP0078 |
CGCACTAATG |
CATTAGTGCG |
TGACTACATA |
TGACTACATA |
TATGTAGTCA |
|
SCUDP0079 |
TCCTGACCGT |
ACGGTCAGGA |
CGGCCTCGTT |
CGGCCTCGTT |
AACGAGGCCG |
|
SCUDP0080 |
CTGGCTTGCC |
GGCAAGCCAG |
CAAGCATCCG |
CAAGCATCCG |
CGGATGCTTG |
|
SCUDP0081 |
ACCAGCGACA |
TGTCGCTGGT |
TCGTCTGACT |
TCGTCTGACT |
AGTCAGACGA |
|
SCUDP0082 |
TTGTAACGGT |
ACCGTTACAA |
CTCATAGCGA |
CTCATAGCGA |
TCGCTATGAG |
|
SCUDP0083 |
GTAAGGCATA |
TATGCCTTAC |
AGACACATTA |
AGACACATTA |
TAATGTGTCT |
|
SCUDP0084V3 |
TAGATCCAGT |
ACTGGATCTA |
TCGCCGCTAG |
TCGCCGCTAG |
CTAGCGGCGA |
|
SCUDP0085 |
TTAGGTACCA |
TGGTACCTAA |
CATGAGTACT |
CATGAGTACT |
AGTACTCATG |
|
SCUDP0086 |
GGAATTCCAA |
TTGGAATTCC |
ACGTCAATAC |
ACGTCAATAC |
GTATTGACGT |
|
SCUDP0087 |
CATGTAGAGG |
CCTCTACATG |
GATACCTCCT |
GATACCTCCT |
AGGAGGTATC |
|
SCUDP0088 |
TACACGCTCC |
GGAGCGTGTA |
ATCCGTAAGT |
ATCCGTAAGT |
ACTTACGGAT |
|
SCUDP0089 |
GCTTACGGAC |
GTCCGTAAGC |
CGTGTATCTT |
CGTGTATCTT |
AAGATACACG |
|
SCUDP0090 |
CGCTTGAAGT |
ACTTCAAGCG |
GAACCATGAA |
GAACCATGAA |
TTCATGGTTC |
|
SCUDP0091 |
CGCCTTCTGA |
TCAGAAGGCG |
GGCCATCATA |
GGCCATCATA |
TATGATGGCC |
|
SCUDP0092 |
ATACCAACGC |
GCGTTGGTAT |
ACATACTTCC |
ACATACTTCC |
GGAAGTATGT |
|
SCUDP0093 |
CTGGATATGT |
ACATATCCAG |
TATGTGCAAT |
TATGTGCAAT |
ATTGCACATA |
|
SCUDP0094 |
CAATCTATGA |
TCATAGATTG |
GATTAAGGTG |
GATTAAGGTG |
CACCTTAATC |
|
SCUDP0095 |
GGTGGAATAC |
GTATTCCACC |
ATGTAGACAA |
ATGTAGACAA |
TTGTCTACAT |
|
SCUDP0096 |
TGGACGGAGG |
CCTCCGTCCA |
CACATCGGTG |
CACATCGGTG |
CACCGATGTG |
|
Well |
Index Name |
i7 Bases in Adapter |
i7 Bases for Sample Sheet |
i5 Bases in Adapter |
i5 Bases for Sample Sheet in Forward Orientation |
i5 Bases for Sample Sheet in Reverse Complement Orientation |
|---|---|---|---|---|---|---|
|
Mix 1 |
SCUDP0017 |
AACCATTCTC |
GAGAATGGTT |
TCGGCAGCAA |
TCGGCAGCAA |
TTGCTGCCGA |
|
Mix 2 |
SCUDP0018 |
GGTTGCCTCT |
AGAGGCAACC |
CTAATGATGG |
CTAATGATGG |
CCATCATTAG |
|
Mix 3 |
SCUDP0019 |
CTAATGATGG |
CCATCATTAG |
GGTTGCCTCT |
GGTTGCCTCT |
AGAGGCAACC |
|
Mix 4 |
SCUDP0020 |
TCGGCCTATC |
GATAGGCCGA |
CGCACATGGC |
CGCACATGGC |
GCCATGTGCG |
|
Mix 5 |
SCUDP0021 |
AGTCAACCAT |
ATGGTTGACT |
GGCCTGTCCT |
GGCCTGTCCT |
AGGACAGGCC |
|
Mix 6 |
SCUDP0022 |
GAGCGCAATA |
TATTGCGCTC |
CTGTGTTAGG |
CTGTGTTAGG |
CCTAACACAG |
|
Mix 7 |
SCUDP0023 |
AACAAGGCGT |
ACGCCTTGTT |
TAAGGAACGT |
TAAGGAACGT |
ACGTTCCTTA |
|
Mix 8 |
SCUDP0024 |
GTATGTAGAA |
TTCTACATAC |
CTAACTGTAA |
CTAACTGTAA |
TTACAGTTAG |