NextSeq 1000/2000 Settings
For descriptions of each field, including the specific requirements and if the expected value is an integer or string, refer to Parameters.
Standalone Sections
Parameter |
Required |
Instrument-Specific Settings |
---|---|---|
FileFormatVersion |
Yes |
|
RunName |
No |
|
RunDescription |
No |
|
InstrumentType |
No |
NextSeq1000 or NextSeq2000 |
InstrumentPlatform |
No |
NextSeq1000 or NextSeq2000 |
Parameter |
Required |
Instrument-Specific Settings |
---|---|---|
Read1Cycles |
Yes |
|
Read2Cycles |
No |
|
Index1Cycles |
No |
Required when sequencing more than one sample. Maximum is 10 cycles. |
Index2Cycles |
No |
Required if using dual indexes for demultiplexing. Maximum is 10 cycles. |
Parameter |
Required |
Instrument-Specific Settings |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LibraryPrepKits |
No |
Only one library prep kit is allowed. In the NextSeq 1000/2000 Control Software v1.3 or later, the required custom recipe is automatically selected if one of the following kits is specified as the library prep kit.
Enter one of the following values.
|
Application Sections
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
AdapterRead1 |
No |
Settings |
Possible values are a concatenation from the set [A,C,T,G]. NextSeq 1000/2000 also allows a blank value. AdapterRead1 trims cycles by default. Value must be ≤ Read1Cycles. |
AdapterRead2 |
No |
Settings |
Possible values are a concatenation from the set [A,C,T,G]. NextSeq 1000/2000 also allows a blank value. AdapterRead2 trims cycles by default. Value must be ≤ Read2Cycles. |
BarcodeMistmatchesIndex1 |
No |
Settings |
|
BarcodeMismatchesIndex2 |
No |
Settings |
|
FastqCompressionFormat |
No |
Settings |
|
OverrideCycles |
No |
Settings |
|
SoftwareVersion |
Yes |
Settings |
|
Sample_ID |
Yes |
Data |
|
Index |
No |
Data |
|
Index2 |
No |
Data |
|
Lane |
No |
Data |
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
SoftwareVersion |
Yes |
Settings |
|
ReferenceGenomeDir |
Yes |
Settings |
For example, hg38_alt_aware. |
BedFile |
Yes |
Settings |
|
GermlineOrSomatic |
Yes |
Settings |
|
KeepFastq |
No |
Settings |
|
MapAlignOutFormat |
No |
Settings |
|
AuxNoiseBaselineFile |
No |
Settings |
|
Sample_ID |
Yes |
Data |
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
SoftwareVersion |
Yes |
Settings |
|
ReferenceGenomeDir |
Yes |
Settings |
For example, hg38_alt_aware. |
MapAlignOutFormat |
No |
Settings |
|
KeepFastq |
No |
Settings |
|
Sample_ID |
Yes |
Data |
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
SoftwareVersion |
Yes |
Settings |
|
ReferenceGenomeDir |
Yes |
Settings |
For example, hg38_alt_aware. |
DnaBedFile |
Yes |
Settings |
|
DnaGermlineOrSomatic |
Yes |
Settings |
|
KeepFastq |
No |
Settings |
|
MapAlignOutFormat |
No |
Settings |
|
Sample_ID |
Yes |
Data |
|
DnaOrRna |
Yes |
Data |
|
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
SoftwareVersion |
Yes |
Settings |
|
ReferenceGenomeDir |
Yes |
Settings |
For example, hg38_alt_aware. |
RnaGeneAnnotationFile |
No |
Settings |
|
MapAlignOutFormat |
No |
Settings |
|
KeepFastq |
No |
Settings |
|
DifferentialExpressionEnable |
No |
Settings |
|
Sample_ID |
Yes |
Data |
|
Comparison<N> |
No |
Data |
The N value reflects the comparison group of the samples. |
Parameter |
Required |
Section |
Instrument-Specific Requirements |
---|---|---|---|
SoftwareVersion |
Yes |
Settings |
|
ReferenceGenomeDir |
Yes |
Settings |
For example, hg38_alt_aware. |
RnaLibraryType |
No |
Settings |
|
RnaGeneAnnotationFile |
No |
Settings |
|
BarcodeRead |
No |
Settings |
|
BarcodePosition |
Yes |
Settings |
The value expected for Single Cell Library Kit Types 1–5 is different than the value for Single Cell Library Kit Types 6. Refer to Parameters for more information. |
UmiPosition |
Yes |
Settings |
|
BarcodeSequenceList |
No |
Settings |
|
KeepFastq |
No |
Settings |
|
MapAlignOutFormat |
No |
Settings |
|
Sample_ID |
Yes |
Data |