Configure Workflows
After protocols are created and configured, add them to workflows that represent how samples move through your lab.
In Clarity LIMS, use the Lab Work configuration screen to view, add, and configure the workflows used in the lab. For an overview of this screen, refer to Lab Work Overview.
To access the Lab Work tab and configure workflows, the Configuration:update permission is required. By default, only the Administrator role has this permission. For details, refer to User Roles and Configure Role-Based Permissions.

The Lab Work screen provides an at-a-glance view of all workflows configured in the LIMS, along with the protocols and steps they contain. You can quickly see which workflows are active, which are archived, and which do not yet have protocols assigned to them.
1. | On the main menu, select Configuration. |
2. | Select the Lab Work tab. |
The Workflows, Protocols, Steps, and Master Steps navigation panel displays. This presents alphabetically sorted lists of all workflows, protocols, steps, and master steps configured in the LIMS.
3. | In the Workflows list, select a workflow to highlight it. |
• | The Protocols list updates to show all protocols included in the workflow. These are highlighted and displayed sequentially at the top of the list. A dashed line separates these workflow protocols from the comprehensive list of all protocols in the system. |
• | The Steps list updates, highlighting the steps included in the highlighted protocols. |
• | The Master Steps list updates, highlighting the master steps on which the highlighted steps are based. |
You can also select a protocol, step, or master step to view the related workflows.
4. | Below the main navigation panel, review the workflow configuration form. This displays the name of the workflow and its status. |
The following table provides an overview of each status setting and describes the implications of each.
Status |
What It Means in the Lab |
Configuration Implications |
|||||||||||||||||||||
Active |
|
|
|||||||||||||||||||||
Pending |
|
|
|||||||||||||||||||||
Archived |
|
|

The following section shows how to add a workflow to the LIMS and add protocols to it. When configuring workflows, keep the following in mind:
• | You are not required to add protocols immediately. If you prefer, you can create empty Pending workflows and assign protocols to them later. |
• | You can only activate a Pending workflow if it contains at least one protocol. |
• | When adding protocols to a workflow, reordering protocols within a workflow, or removing protocols from a workflow, your changes are autosaved. You do not have to select Save after every modification. |
• | You cannot add empty protocols to a workflow. The protocol must include steps. |
To add a new workflow:
1. | On the Lab Work configuration screen, in the upper-right corner of the Workflow list, select Add. |
2. | Below the main navigation panel, the workflow configuration form displays. |
3. | To begin, type a name for your new workflow. |
4. | Select Save. |
The workflow is saved in a Pending state, and displays in the Workflow list of the main navigation panel.
To add protocols to a workflow:
1. | In the Workflow list, select the workflow. |
2. | In the Protocol list, locate the first protocol to include and select Add. |
The protocol is added to the workflow and displays at the top of the Protocol list. The 1 indicates that this is the first protocol in the workflow.
3. | Repeat step 2 until you have added all required protocols to the workflow. |
• | To remove a protocol from the workflow, select its Remove button. |
• | Drag and drop to reorder protocols within the workflow. |
• | To drag and drop on a mobile or touch-screen device, touch and hold the item you wish to drag. After a moment, the item appears to lift off the page and its color changes to white. You can then drag the item and drop it into its new position. |
• | To view or modify a protocol, select the protocol to display its configuration form below the main navigation pane. |
4. | You can now save the workflow as a Pending workflow. |
- or -
Select Activate to use this workflow immediately.
After you activate a workflow, you cannot modify or delete it.

1. | On the Lab Work configuration screen, in the Workflow list, select the Pending workflow to modify or activate. |
2. | Make your changes and select Save to save the workflow as a Pending workflow. |
-or-
Select Activate to change the workflow status to Active and begin using the workflow.
When modifying or activating workflows, keep the following in mind:
• | You cannot activate empty workflows. |
• | You can only modify a workflow while it remains in the Pending state. That is: |
– | You cannot add a protocol to an Active or Archived workflow. |
– | You cannot remove a protocol from an Active or Archived workflow. |
– | You cannot rename or reorder protocols in an Active or Archived workflow. |
– | You cannot delete protocols included in Active or Archived workflows. |

While you cannot delete workflows after they have been activated, you can archive them. This makes them temporarily unavailable for use in the lab. You can reactivate an Archived workflow at any time.
To archive a workflow:
1. | On the Lab Work configuration screen, in the Workflow list, select the Active workflow to archive. |
2. | In the Workflow Settings area, select Archive. Select Save. |
To reactivate an archived workflow:
1. | On the Lab Work configuration screen, in the Workflow list, select the Archived workflow to reactivate. |
2. | In the Workflow Settings area, select Activate. Select Save. |

1. | On the Lab Work configuration screen, in the Workflow list, select the pending workflow to delete. |
2. | On the workflow configuration form, select Delete. |
3. | Confirm the workflow deletion: |
• | To proceed with the deletion, select Delete. |
• | To cancel the deletion, select Cancel. |
You can only delete a workflow while the workflow remains in the Pending state. You cannot delete Active or Archived workflows.