AmpliSeq for Illumina Transcriptome Human Gene Expression Panel
The AmpliSeq for Illumina Transcriptome Human Gene Expression Panel includes the following functionality:
| • | Preconfigured AmpliSeq for Illumina Transcriptome Human Gene Expression Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of total RNA using the AmpliSeq for Illumina workflow. |
| • | Automated calculation of sample and buffer volumes. Automated calculation or display of reagents at every step in the protocol. |
| • | Automatic step transition when required. |
| • | Automatic placement of samples when necessary. |
| • | Automated assignment of QC Pass/Fail, based on user-selected threshold values. |
| • | There is no extraction protocol in this workflow because the samples are already extracted. |
Protocol 1: RNA Library Prep (AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.0)
Master Step 1: Dilute RNA (AmpliSeq for Illumina v1.0)
Step Type: Standard
Input = RNA with concentration
Output = Diluted RNA (1-100 ng)
Placement
| • | Master Step |
| • | None |
| • | Step |
| • | Tube |
Record Details
| • | Step Data |
| • | Master Step Fields |
| • | Desired Concentration (ng/uL) |
| • | Numeric |
| – | Range 20 - 50 |
| • | Multiline Text Fields |
| • | Directions |
| • | Multi-line text |
| – | Preset = If enough DNA is available, dilute to intermediate concentration ~20-50 ng/uL. |
| – | Read only |
| • | Step File Placeholders |
| • | Log |
| • | Auto |
| • | Table Columns |
| • | Concentration |
| • | Numeric |
| – | Conc. Units |
| – | Single-line text |
| – | Input Amount (ng) |
| – | Numeric |
| – | Nuclease-free water (uL) |
| – | Numeric |
| – | Sample Volume (uL) |
| – | Numeric |
| – | Total Volume (uL) |
| – | Numeric |
Automation - Script description
| • | Copy Concentration and Set Sample Volume |
| • | Trigger location: Record Details |
| – | Trigger Style: Automatic upon entry |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Concentration:: = input.::Concentration:: ; output.::Conc. Units:: = input.::Conc. Units:: ; output.::Sample Volume (uL):: = 5' \-log {compoundOutputFileLuid0}["]
| • | Calculate Input Amount |
| • | Trigger location: Record Details |
| – | Trigger Style: manual button |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t true \-h false \-exp 'output.::Total Volume (uL):: = (output.::Concentration::/step.::Desired Concentration (ng/uL)::) * output.::Sample Volume (uL):: ; \output.::Nuclease-free water (uL):: = output.::Total Volume (uL):: - output.::Sample Volume (uL):: ; \output.::Input Amount (ng):: = step.::Desired Concentration (ng/uL):: * output.::Sample Volume (uL):: ' \-log {compoundOutputFileLuid0}["]
| • | Copy Desired Concentration |
| • | Trigger location: Step |
| – | Trigger Style: Automatic upon exit |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Desired Concentration (ng/uL):: = step.::Desired Concentration (ng/uL)::' \-log {compoundOutputFileLuid0}["]
[Optional] Next Steps:
| • | Qubit (AmpliSeq for Illumina Immune Response Panel v1.0) |
| • | Reverse Transcribe RNA (AmpliSeq for Illumina Immune Response Panel v1.0) |
Start Next Step - manual
Assign Next Step - Manual
Must move forward.
Master Step 2: Qubit (AmpliSeq for Illumina v1.0)
Step Type: Standard QC
Input = Diluted RNA (1-100 ng)
Output = Measurement
Placement
| • | Master Step |
| • | None |
| • | Step |
| • | Tube |
Record Details
| • | Step Data |
| • | Master Step Fields |
| • | Criteria 1 - Source Data Field |
| • | Text |
| – | Preset = Concentration |
| – | Criteria 1 - Operator |
| – | Text |
| – | Preset: >= |
| – | Criteria 1 - Threshold Value |
| – | Numeric |
| – | Criteria 2 - Source Data Field |
| – | Text |
| – | Preset = Concentration |
| – | Criteria 2 - Operator |
| – | Text |
| – | Preset: <= |
| – | Criteria 2 - Threshold Value |
| – | Numeric |
| • | Step File Placeholders |
| • | Log |
| • | Auto |
| – | QC Log File |
| – | Auto |
| – | QC Result File |
| – | Manual |
| – | Upload File |
| – | Manual |
| • | Table Columns |
| • | Concentration |
| • | Derived Sample |
| – | Numeric |
| – | Conc. Units |
| – | Derived Sample |
| – | Text |
Automation - Script description
| • | Assign QC Flags |
| • | Trigger location: Record Details |
| – | Trigger Style: Manual button |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {processURI:v2} -u {username} -p {password} script:assignQC -log {compoundOutputFileLuid1} -qcResult {compoundOutputFileLuid2}"
| – | Set Next Step and Copy Concentration |
| – | Trigger location: Record Details |
| – | Trigger Style: Automatic upon exit |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} script:evaluateDynamicExpression -t false -h false -exp 'nextStep = ::ADVANCE:: ; input.::Concentration:: = output.::Concentration:: ; input.::Conc. Units:: = output.::Conc. Units::' -log {compoundOutputFileLuid0}"
Start Next Step - Automatic
Assign Next Step - Automatic
Must move forward.
Master Step 3: Dilute RNA (AmpliSeq for Illumina v1.0)
Step Type:
Input = Diluted RNA with concentration
Output = Diluted RNA (1-100 ng)
Place Samples = Tube
Record Details =
| • | PlaceholderLog |
| • | Step UDF Desired Concentration (ng/uL) |
| • | Range 20 - 50 |
| • | Analyte UDF = Concentration |
| • | Numeric |
| – | Conc. Units |
| – | Single-line text |
| – | Input Amount (ng) |
| – | Numeric |
| – | Nuclease-free water (uL) |
| – | Numeric |
| – | Sample Volume (uL) |
| – | Numeric |
| – | Total Volume (uL) |
| – | Numeric |
| • | Script description |
| • | Copy Concentration and Set Sample Volume |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Concentration:: = input.::Concentration:: ; output.::Conc. Units:: = input.::Conc. Units:: ; output.::Sample Volume (uL):: = 5' \-log {compoundOutputFileLuid0}["]
| – | Calculate Input Amount |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t true \-h false \-exp 'output.::Total Volume (uL):: = (output.::Concentration::/step.::Desired Concentration (ng/uL)::) * output.::Sample Volume (uL):: ; \output.::Nuclease-free water (uL):: = output.::Total Volume (uL):: - output.::Sample Volume (uL):: ; \output.::Input Amount (ng):: = step.::Desired Concentration (ng/uL):: * output.::Sample Volume (uL):: ' \-log {compoundOutputFileLuid0}["]
| – | Set Next Step - Advance and Set Desired Conc |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE:: ; output.::Desired Concentration (ng/uL):: = step.::Desired Concentration (ng/uL)::' \-log {compoundOutputFileLuid0}["]
| – | Copy Desired Concentration |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Desired Concentration (ng/uL):: = step.::Desired Concentration (ng/uL)::' \-log {compoundOutputFileLuid0}["]
Next Steps:
Reverse Transcribe RNA (AmpliSeq for Illumina Immune Response Panel v1.0)
| • | Automatic Transition |
Master Step 4: Reverse Transcribe RNA (AmpliSeq for Illumina v1.0)
Input = RNA with concentration
Output = Reverse Transcribed RNA
Place Samples = 96 well plate
Reagent Kits =
| • | AmpliSeq cDNA Synthesis for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 20022654 |
| – | Website - www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF Directions (multi-line text) |
| • | If RNA was prepared from FFPE tissue and never heat-treated, heat at 80°C for 10 minutes and then cool to room temperature before proceeding to reverse transcription. |
| – | AmplISeq ERCC RNA Spike-in Mix (toggle) |
| – | AmpliSeq ERCC RNA Spike-in Mix for Illumina (uL) (Number - 2 decimal places, range = 0-2, default = 0) |
| – | AmpliSeq ERCC RNA Spike-in Mix for Illumina Lot# (Text) |
| – | Thermal Cycler Program |
| – | Preset = RT |
| – | 5X AmpliSeq cDNA Reaction Mix (uL) |
| – | 10X AmpliSeq RT Enzyme Mix (uL) |
| – | Nuclease-free water (uL) |
| – | Prep Input Volume (uL) |
| – | Calculated |
| – | Numeric |
| – | Prep Input Amount (ng) |
| – | User input |
| – | Mandatory |
| – | Range - 1-100 |
| – | Total Samples |
Analyte UDF = Concentration
| – | Conc. Units |
| – | Total Volume (uL) |
| – | Numeric |
| – | Input Amount (ng) |
| – | AmpliSeq ERCC RNA Spike-in Volume (uL) |
| • | Script description |
| • | Copy Concentration, Total Volume and Input Amount |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Concentration:: = input.::Concentration:: ; \output.::Conc. Units:: = input.::Conc. Units:: ; \output.::Total Volume (uL):: = input.::Total Volume (uL):: ; \output.::Input Amount (ng):: = input.::Input Amount (ng):: ; \step.::Desired Concentration (ng/uL):: = input.::Desired Concentration (ng/uL)::' \-log {compoundOutputFileLuid0}["]
| – | Calculate Input Amount - Transcriptome Human Genome Expression Panel |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t true \-h false \-exp 'step.::Prep Input Volume (uL):: = step.::Prep Input Amount (ng):: / step.::Desired Concentration (ng/uL):: ; \if (step.::Prep Input Volume (uL):: < 7.0) {step.::Nuclease-free water (uL):: = (7.0 - (step.::Prep Input Volume (uL):: + output.::AmpliSeq ERCC RNA Spike-in Volume (uL)::)) * step.::Total Samples::*1.1} else {step.::Nuclease-free water (uL):: = 0} ; \step.::5X AmpliSeq cDNA Reaction Mix (uL):: = step.::Total Samples:: * 1.1 * 1 ; \step.::10X AmpliSeq RT Enzyme Mix (uL):: = step.::Total Samples:: * 1.1 * 0.5 ; \step.::AmpliSeq ERCC RNA Spike-in Mix (uL):: = step.::Total Samples:: * output.::AmpliSeq ERCC RNA Spike-in Volume (uL):: *1.1' \-log {compoundOutputFileLuid0}["]
| – | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
| • | Automatic Transition |
Master Step 5: Amplify cDNA Targets Standard (AmpliSeq for Illumina v1.0) >> New Master Step with with no reps = variable output = 1.
Input = Reverse Transcribed RNA
Output = cDNA
Place Samples = 96 well plate
Variable Outputs = 1
Sample Name = {InputItemName}_{OutputItemSubsetNumber}
Reagent Kits =
| • | AmpliSeq Library PLUS for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 24 - 20019101; 96 - 200191102; 384 - 200191103 |
| – | Website - www.illumina.com |
| • | AmpliSeq Transcriptome Gene Expression Panel for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 20019170 |
| – | Website - www.illumina.com |
Record Details =
| • | PlaceholderLog |
| • | Step UDF Thermal Cycler ProgramPreset = AMP_RNA |
| – | AmpliSeq ERCC RNA Companion Panel for Illumina (toggle) |
| – | AmpliSeq ERCC RNA Companion Panel for Illumina Lot# (text) |
| – | 5X AmpliSeq HiFi Mix (uL) |
| – | Decimal Places = 2 |
| – | Nuclease-free water (uL) |
| – | Decimal Places = 2 |
| – | PCR Cycles |
Analyte UDF = None
| • | Script description |
Set Sample Type and Calculate Master Mix - TGx Panel
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \script:evaluateDynamicExpression \-t false \-h false \-exp 'output.::Sample Type:: = ::cDNA:: ; \step.::5X AmpliSeq HiFi Mix (uL):: = 4 * step.::Total Samples:: * 1.1 ; \step.::Nuclease-free water (uL):: = 3 * step.::Total Samples:: * 1.1' \-log {compoundOutputFileLuid0}["]
| – | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Master Step 6: Partially Digested Amplicons (AmpliSeq for Illumina v1.0)
Input = Pooled samples
Output = Partially Digested Amplicons
No Output
Reagent Kits =
| • | AmpliSeq Library PLUS for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 24 - 20019101; 96 - 200191102; 384 - 200191103 |
| – | Website - www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF Thermal Cycler Program |
| • | Preset FUPA |
| • | Script description |
| • | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Safe Stopping Point
Master Step 7: Ligate Indexes (AmpliSeq for Illumina v1.0)
Input = Partially Digested Amplicons
Output = Ligated Libraries
Place Samples = 96 well plate
Add Labels
Reagent Kits =
| • | AmpliSeq Library PLUS for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 24 - 20019101; 96 - 200191102; 384 - 200191103 |
| – | Website - www.illumina.com |
Index List (5.x)
| • | AmpliSeq CD Indexes Set A for Illumina - AmpliSeq CD Indexes Set A for Illumina-label-sheet.xlsx |
| • | AmpliSeq CD Indexes Set B for Illumina - AmpliSeq CD Indexes Set B for Illumina-label-sheet.xlsx |
| • | AmpliSeq CD Indexes Set C for Illumina - AmpliSeq CD Indexes Set C for Illumina-label-sheet.xlsx |
| • | AmpliSeq CD Indexes Set D for Illumina - AmpliSeq CD Indexes Set D for Illumina-label-sheet.xlsx |
| • | AmpliSeq UD Indexes for Illumina (24 Indexes) - AmpliSeq UD Indexes for Illumina (24 Indexes)-label-sheet.xlsx |
Record Details =
| • | Placeholder |
| • | Log File |
| • | Step UDF |
| • | Thermal Cycler Program |
| • | Preset LIGATE |
| • | Analyte UDF AmpliSeq Workflow Presets |
| • | Standard Workflow or Equalizer Workflow |
| – | Mandatory |
Script description
Set Next Step - Advance
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Route AmpliSeq Samples -Transcriptome Human GEx Panel
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -u {username} -p {password} -i {stepURI:v2} -l {compoundOutputFileLuid0} script:changeWorkflow \ \--FIELD_NAME 'AmpliSeq Workflow' \--FIELD_VALUE 'Standard Workflow' \--WORKFLOW 'Standard Workflow AmpliSeq for Illumina Immune Response Panel v1.0' \--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Response Panel v1.0)' \--INPUTS_OR_OUTPUTS 'OUTPUTS' \\--FIELD_NAME 'AmpliSeq Workflow' \--FIELD_VALUE 'Equalizer Workflow' \--WORKFLOW 'Equalizer Workflow AmpliSeq for Illumina Immune Response Panel v1.0' \--STEP 'Clean Up Library (AmpliSeq for Illumina Immune Response Panel v1.0)' \--INPUTS_OR_OUTPUTS 'OUTPUTS'["]
Safe Stopping Point
Protocol 2: Standard Workflow (AmpliSeq for Illumina Transcriptome Human Gene Expression Panel v1.0)
Master Step 1: Clean Up Library (AmpliSeq for Illumina v1.0)
Input = Ligated Libraries
Output = Cleaned Up Libraries
No Output
Reagent Kits =
| • | Agencourt AMPure XP Beads |
| • | Supplier - Thermo |
| – | Cat. # - NC9959336; NC9933872 |
Record Details =
| • | Placeholder |
| • | Log File |
| • | Step UDF |
| • | 70% EtOH Prep Date |
| • | Date |
| • | Script description |
| • | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Automatic Transition
Master Step 2: Amplify Library (AmpliSeq for Illumina v1.0)
Input = Cleaned Up Libraries
Output = Amplified Libraries
No Output
Reagent Kits =
| • | Agencourt AMPure XP Beads |
| • | Supplier - Thermo |
| – | Cat. # - NC9959336; NC9933872 |
| • | AmpliSeq Library PLUS for Illumina |
| • | Supplier - Illumina |
| – | Cat. # - 24 - 20019101; 96 - 200191102; 384 - 200191103 |
| – | Website - www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF |
| • | Thermal Cycler Program |
| – | Total Samples |
| – | Preset 0 |
| – | 1X Lib AMP Mix (uL) |
| – | Numeric |
| – | 10X Library Amp Primers (uL) |
| – | Numeric |
| – | Group of Defaults Standard Workflow = AMP_7 |
| • | Script description Calculate Total Samples and Calculate Master Mix |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::1X Lib Amp Mix:: = step.::Total Samples:: * 1.1 * 45 ; \step.::10X Library Amp Primers:: = step.::Total Samples:: * 1.1 * 5' \-log {compoundOutputFileLuid0}["]
| – | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Safe Stopping Point
Master Step 3: Perform Second Clean Up (AmpliSeq for Illumina BRCA Panel v1.0)
Input = Amplified Libraries
Output = Cleaned Up Amplified Libraries
Place Samples = 96 well plate
Reagent Kits =
| • | Agencourt AMPure XP BeadsSupplier - Thermo |
| – | Cat. # - NC9959336; NC9933872 |
| • | AmpliSeq Library PLUS for IlluminaSupplier - Illumina |
| – | Cat. # - 24 - 20019101; 96 - 200191102; 384 - 200191103 |
| – | Website - www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF |
| • | 70% EtOH Prep Date |
| • | Date |
| • | Script description |
| • | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Protocol 4: Equalizer Workflow (AmpliSeq for Illumina Childhood Cancer Panel v1.0)
Master Step 1: Clean Up Library (AmpliSeq for Illumina v1.0)
Input = Ligated Libraries
Output = Cleaned Up Libraries
No Output
Reagent Kits =
| • | Agencourt AMPure XP Beads |
| • | Supplier - Thermo |
| – | Cat. # - NC9959336; NC9933872 |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF 70% EtOH Prep Date |
| • | Date |
| • | Script description |
| • | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Automatic Transition
Master Step 2: Amplify Library (AmpliSeq for Illumina v1.0)
Input = Cleaned Up Libraries
Output = Amplified Libraries
No Output
Reagent Kits =
| • | Agencourt AMPure XP Beads |
| • | AmpliSeq Library PLUS for Illumina |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF |
| • | Thermal Cycler Program |
| – | Total Samples |
| – | Preset 0 |
| – | 1X Lib AMP Mix (uL) |
| – | Numeric |
| – | 10X Library Amp Primers (uL) |
| – | Numeric |
| • | Group of Defaults = Equalizer Workflow |
| • | Thermal Cycler Program = EQUAL |
Script description Calculate Total Samples and Calculate Master Mix
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \-log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \script:evaluateDynamicExpression \-t false \-h false \-exp 'step.::1X Lib Amp Mix:: = step.::Total Samples:: * 1.1 * 45 ; \step.::10X Library Amp Primers:: = step.::Total Samples:: * 1.1 * 5' \-log {compoundOutputFileLuid0}["]
| – | Set Next Step - Advance |
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
| • | Automatic Transition |
Master Step 3: Perform Capture and Clean Up (AmpliSeq for Illumina v1.0)
Input = Amplified Libraries
Output = Cleaned Up Libraries
Place Samples = 96 well plate
Reagent Kits =
| • | AmpliSeq Library Equalizer for Illumina |
| • | Supplier = Illumina |
| – | Cat. # = |
| – | Website = www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
Script description
Set Next Step - Advance
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]
Automatic Transition
Master Step 4: Elute Library (AmpliSeq for Illumina v1.0)
Input = Cleaned Up Libraries
Output = Final Library
Place Samples = 96 well plate
Reagent Kits =
| • | AmpliSeq Library Equalizer for Illumina |
| • | Supplier = Illumina |
| – | Cat. # = |
| – | Website = www.illumina.com |
Record Details =
| • | Placeholder |
| • | Log |
| • | Step UDF |
| • | Thermal Cycler Program |
| – | Present ELUTE |
Script description
Set Next Step - Advance
bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \-t false \-h false \-exp 'nextStep = ::ADVANCE::' \-log {compoundOutputFileLuid0}["]