Illumina Preset Protocol - Nextera Flex for Enrichment
Protocol 1: Prep Sample (Nextera Flex for Enrichment)
Master Step 1: Sort Sample (Nextera Flex for Enrichment)
Master Step type: No outputs
Input = Blood, Saliva, gDNA, FFPE DNA
Output = Blood Lysis, Saliva Lysis, gDNA, FFPE DNA
Placement = none
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step File Placeholders |
|
File Name |
Log |
|||||||||||||
|
Sample Table |
Table Columns |
Sample Type |
Text Dropdown |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Sort and Set Next Step |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 2: Blood Lysis (Nextera Flex for Enrichment)
This protocol is expected to generate > 100 ng of DNA output at the end of the blood lysis step.
Step type: Standard
Input = Blood
Output = Blood Lysis
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Flex Lysis Reagent Kit |
Illumina |
20015884 |
|
Agencourt AMPure XP beads, 5 ml |
Beckman Coulter |
A63880 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Placement Pattern |
Column |
|
Placement Screen |
Manual |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Preset
|
|||
|
Total Samples |
Numeric |
Calculated - Total Samples + 1 |
|||||
|
BLB (uL) |
Numeric |
Calculated = Total Samples * 7 * 1.1 |
|||||
|
PK1 (uL) |
Numeric |
Calculated = Total Samples * 2 * 1.1 |
|||||
|
Water (uL) |
Numeric |
Calculated = Total Samples * 31 * 1.1 |
|||||
|
80% EtOH Prep Date |
Date |
||||||
|
Step File Placeholders |
|
File Name |
Log |
||||
|
Sample Table |
Table Columns |
NFE Sample Type |
Text |
Copy from previous step |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Total Samples and Master Mix |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Set Next Step - Remove and Copy NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|||
|
Route NFE - Blood |
Trigger Location |
Step |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 3: Saliva Lysis (Nextera Flex for Enrichment)
Master Step Type: Standard
Input = Saliva
Output = Saliva Lysis
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Agencourt AMPure XP beads, 5 ml |
Beckman Coulter |
A63880 |
|
Setting |
Value |
Specification |
|---|---|---|
|
Destination Containers |
96 well plate |
Configured on step |
|
Placement Pattern |
Column |
|
|
Placement Screen |
Manual |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
80% EtOH Prep |
Date |
||||
|
Step File Placeholders |
|
File Name |
Log |
Auto |
|||
|
Sample Table |
Table Columns |
NFE Sample Type |
Text |
Copy from previous step |
|||
|
Sample Volume (uL) |
Numeric |
Preset
|
|||||
|
80% EtOH (uL) |
Numeric |
Preset
|
|||||
|
Water for Resuspension (uL) numeric |
Numeric |
Preset
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Copy NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Set Next Step - Remove & Copy NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|||
|
Route NFE - Saliva |
Trigger Location |
Step |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 4: Qubit gDNA QC (Nextera Flex for Enrichment)
Master Step Type: Standard QC
Input = gDNA ( 10–1000 ng)
Output = Measurement
|
Setting |
Value |
|---|---|
|
Destination Containers |
Tube |
|
Placement Screen |
Auto |
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Criteria 1 - Source Data Field |
Concentration |
|
|
Criteria 1 - Operator |
>= |
|||
|
Criteria 1 - Threshold Value |
|
|||
|
Criteria 2 - Source Data Field |
Concentration |
|||
|
Criteria 2 - Operator |
<= |
|||
|
Criteria 2 - Threshold Value |
|
|||
|
Step File Placeholders |
|
File Name |
Log |
|
|
QC Log File |
||||
|
QC Result File |
||||
|
Upload File |
||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
|
|
Conc. Units |
Text |
|||
|
NFE Sample Type |
Text |
Copy from previous step |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Assign QC Flags |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Set Next Step and Copy Concentration |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Master Step 5: Dilute gDNA (Nextera Flex for Enrichment)
Master Step Type: Standard
Input = gDNA with concentration
Output = Diluted DNA (10-1000 ng)
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Placement Pattern |
Column |
|
Placement Screen |
Manual |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Desired gDNA Input (ng) |
10-1000 |
|||||||
|
Dilution Buffer |
Text Dropdown |
|
||||||||
|
Sample Volume (uL)Numeric |
Preset
|
|||||||||
|
Notes |
Multiline Text |
Preset
|
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|||||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
Value from previous step |
||||||
|
Conc. Units (ng/uL) |
Text |
|||||||||
|
Total Volume (uL) |
Numeric |
Calculated = (Concentration * Sample Volume (uL)) / Desired gDNA Input (ng) |
||||||||
|
Dilution Volume (uL) |
Numeric |
Calculated = Total Volume (uL) - Sample Volume (uL) |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Copy Concentration |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Calculate Dilution Volume and Total Volume |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual |
||
|
Command line
|
|||
|
Set Next Step - Remove and Copy NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|||
|
Route NFE - gDNA |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Master Step 6: Qubit FFPE DNA QC (Nextera Flex for Enrichment)
Step Type: Standard QC
Input = FFPE DNA (5 0–1000 ng)
Output = Measurement
Standard QC
|
Setting |
Value |
|---|---|
|
Destination Containers |
Tube |
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Criteria 1 - Source Data Field |
Concentration |
|
|
Criteria 1 - Operator |
>= |
|||
|
Criteria 1 - Threshold Value |
|
|||
|
Criteria 2 - Source Data Field |
Concentration |
|||
|
Criteria 2 - Operator |
<= |
|||
|
Criteria 2 - Threshold Value |
|
|||
|
Step File Placeholders |
|
File Name |
Log |
|
|
QC Log File |
||||
|
QC Result File |
||||
|
Upload File |
||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
Global field - derived sample & measurement |
|
Conc. Units |
Text |
Global field - derived sample & measurement |
||
|
NFE Sample type |
Text |
Copy from previous step |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Assign QC Flags |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Set Next Step and Copy Concentration |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Master Step 7: Dilute FFPE DNA (Nextera Flex for Enrichment)
Input = FFPE DNA
Output = Diluted DNA (50-1000 ng)
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Desired gDNA Input (ng) |
50-1000 |
|||||||
|
Dilution Buffer |
Text Dropdown |
|
||||||||
|
Sample Volume (uL) |
Numeric |
Preset
|
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|||||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
Value from previous step |
||||||
|
Conc. Units (ng/uL) |
Text |
|||||||||
|
Total Volume (uL) |
Numeric |
Calculated = (Concentration * Sample Volume (uL)) / (Desired gDNA Input (ng) * 5) |
||||||||
|
Dilution Buffer (uL) |
Numeric |
Calculated = Total Volume (uL) - Sample Volume (uL) |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Copy Concentration |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Calculate Dilution Volume and Total Volume |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual |
||
|
Command line
|
|||
|
Set Next Step - Advance and Copy NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Protocol 2: Library Prep (Nextera Flex for Enrichment)
Master Step 1: Tagment Genomic DNA (Nextera Flex for Enrichment)
Input = DNA, Blood Lysis, Saliva Lysis
Output = Tagmented DNA
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Default
|
|||||||
|
Total Samples |
Preset
|
|||||||||
|
eBLT (uL) |
Numeric |
Calculated = Total Samples * 11.5 |
||||||||
|
TB1 (uL) |
Numeric |
Calculated = Total Samples * 11.5 |
||||||||
|
Desired Input Amount (ng) |
Numeric |
Range = 50 - 1000 ng |
||||||||
|
Total Volume (uL) |
Numeric |
Preset
|
||||||||
|
Multiline Text Fields |
Notes |
Multiline Text |
Desired Input Amount should be between 50-1000 ng. |
|||||||
|
Step File Placeholders |
|
File Name |
Log |
|||||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
Value from previous step |
||||||
|
Conc. Units (ng/uL) |
Text |
|||||||||
|
Sample Volume (uL) |
Numeric |
Calculated = Concentration / Desired Input Amount (ng) |
||||||||
|
Nuclease-free water (uL) numeric |
Numeric |
Calculated = Total Volume (uL) - Sample Volume (uL) |
||||||||
|
NFE Sample Type |
Text |
Copy from previous step |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Total Samples and Master Mix & Copy Conc. & NFE Sample Type |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Calculate Sample Volume and Water |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual |
||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Master Step 2: Post Tagmentation Cleanup (Nextera Flex for Enrichment)
Step Type: No Outputs
Input = Tagmented DNA
Output = Cleaned Up Tagmented DNA
Placement = none
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must move forward |
|
Master Step 3: Amplify Tagmented DNA (Nextera Flex for Enrichment)
Step Type: Add Labels
Input = Cleaned up Tagmented DNA
Output = Amplifed Tagmented DNA
Placement = none, using the sample 96 well plate as the previous step.
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Label Groups |
IDT for Illumina Nextera DNA UD Indexes Set A (96 Indexes, 96 Samples) |
|
IDT for Illumina Nextera DNA UD Indexes Set B (96 Indexes, 96 Samples) |
|
|
IDT for Illumina Nextera DNA UD Indexes Set C (96 Indexes, 96 Samples) |
|
|
IDT for Illumina Nextera DNA UD Indexes Set D (96 Indexes, 96 Samples) |
|
|
IDT for Illumina Nextera DNA UD Indexes Set A, B, C, D (384 Indexes, 384 Samples) |
Location of indexes = UDP Run Setup Resources
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Preset
|
||||||
|
PCR Cycles |
Numeric |
Preset
|
||||||||
|
Total Samples |
Numeric |
Preset
|
||||||||
|
EPM (uL) |
Numeric |
Calculated = Total Samples * 23 *1.1 |
||||||||
|
Nuclease-free water (uL) |
Numeric |
Calculated = Total Samples * 23 *1.1 |
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Total Samples & Master Mix and Copy NFE Sample Type - NFE Amplify |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 4: Clean Up Libraries (Nextera Flex for Enrichment)
Step Type: Standard
Input = Amplifed Tagmented DNA
Output = Cleaned up libraries
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Agencourt AMPure XP purification beads |
Beckman Coulter |
A63880 |
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step Data |
Master Step Fields |
80% EtOH prep date |
Date |
|
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 5: Bioanalyzer QC Qualify Pre-Enriched Libraries (Nextera Flex for Enrichment)
Step Type: Standard QC
Input = Enriched DNA Fragments
Output = Result File
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Criteria 1 - Source Data Field |
Preset
|
||||
|
Criteria 1 - Operator |
Preset
|
||||||
|
Criteria 1 - Threshold |
Preset
|
||||||
|
Criteria 1 - Source Data Field |
Preset
|
||||||
|
Criteria 1 - Operator |
Preset
|
||||||
|
Criteria 1 - Threshold |
Preset
|
||||||
|
Use strict matching for Bioanalyzer results |
Preset
|
||||||
|
Step File Placeholders |
|
File Name |
Placeholder Bioanalyzer Input File |
Auto |
|||
|
Bioanalyzer Input File Generation |
|||||||
|
Log File |
Auto |
||||||
|
Bioanalyzer XML Result File (required) |
Manual |
||||||
|
Result File (optional) |
Manual |
||||||
|
PDF Summary File (optional) |
Manual |
||||||
|
Bioanalyzer XML Parsing Log File |
Auto |
||||||
|
QC Assignment Log File |
Auto |
||||||
|
QC Assignment Report |
Auto |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Generate Bioanalyzer Input File |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Parse Bioanalyzer XML and Assign QC flags |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|
Setting |
Value |
||||||
|---|---|---|---|---|---|---|---|
|
Start Next Step |
Manual |
||||||
|
Safe Stopping Point |
Optional
|
Master Step 6: Pool Pre-Enriched Libraries (Nextera Flex for Enrichment)
Step Type: Standard
Input = Diluted Pre-Enriched Libraries
Output = Pooled Pre-Enriched Libraries
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Agencourt AMPure XP purification beads |
Beckman Coulter |
A63880 |
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
Tube |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Library Pool Plexity |
Text DropDown |
|
||||||
|
Total Pooled Volume (uL) |
Numeric |
Preset Read Only
|
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|||||||
|
Sample Table |
Table Columns |
Pre-Enriched Library Volume (uL) |
Numeric |
Calculated = if Library Pool Plexity = 1-plex then Pre-Enriched Library Volume (uL) = 14 otherwise pre-enriched library volume (uL) = 2.5 |
||||||
|
RSB Volume (uL) |
Numeric |
Calculated = Total Pooled Volume (uL) - Pre-Enriched Library Volume (uL) |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Pre-Enriched Library Volume and RSB Volume |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|
Setting |
Value |
|||
|---|---|---|---|---|
|
Start Next Step |
Manual
|
|||
|
Assign Next Step |
Automatic |
|||
|
Safe Stopping Point |
|
Master Step 7: Qubit (Nextera Flex for Enrichment)
Step Type: Standard QC
Input = Cleaned Up Libraries
Output = Measurement
|
Setting |
Value |
|---|---|
|
Destination Containers |
Tube |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Criteria 1 - Source Data Field |
Text |
Preset
|
|||
|
Criteria 1 - Operator |
Text |
Preset
|
|||||
|
Criteria 1 - Threshold Value |
Numeric |
|
|||||
|
Criteria 2 - Source Data Field |
Text |
Preset
|
|||||
|
Criteria 2 - Operator |
Text |
Preset
|
|||||
|
Criteria 2 - Threshold Value |
Numeric |
|
|||||
|
Step File Placeholders |
|
File Name |
Log |
||||
|
QC Log File |
|||||||
|
QC Result File |
|||||||
|
Upload File |
|||||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
||||
|
Conc. Units |
Text |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Assign QC Flags |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual Button |
||
|
Command line
|
|||
|
Set Next Step and Copy Concentration |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 8: Pool Pre-Enriched Libraries (Nextera Flex for Enrichment)
(This is the Drop-down text)
Step Type: Standard
Input = Diluted Pre-Enriched Libraries
Output = Pooled Pre-Enriched Libraries
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Agencourt AMPure XP purification beads |
Beckman Coulter |
A63880 |
|
Nextera DNA Flex Pre-Enrichment Library Prep and Enrichment Reagents |
Illumina |
16 - 20025523; 96 - 20025524 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
Tube |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Library Pool |
Text Dropdown |
|
||||||
|
Pre-Enriched Library Sample (ng) |
Numeric |
Preset Read Only
|
||||||||
|
Total Pooled Volume (uL) |
Numeric |
Preset Read Only
|
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|||||||
|
Sample Table |
Table Columns |
Concentration |
Numeric |
Copy from previous step |
||||||
|
Conc. Unit |
Text |
Copy from previous step |
||||||||
|
Pre-Enriched Library Volume (uL) |
Numeric |
Calculated = Pre-Enriched Library Sample (ng)/Concentration |
||||||||
|
RSB Volume (uL) |
Numeric |
Calculated = Total Pooled Volume (uL) - Pre-Enriched Library Volume (uL) |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Copy Concentration |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Calculate Pre-Enriched Library Volume and RSB Volume |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual button |
||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 9: Hybridize Probes (Nextera Flex for Enrichment)
Input = Pooled Pre-Enriched Libraries
Output = Hybridized Probes
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Illumina Exome Panel (8 Enrichment Reactions) (CEX)(optional) |
Illumina |
20020183 |
|
TruSight One (6 Enrichment Reactions) (TOO)(optional) |
Illumina |
20029227 |
|
TruSight One Expanded (6 Enrichment Reactions) (TOE)(optional) |
Illumina |
20029226 |
|
TruSight Cancer (8 Enrichment Reactions)(optional) |
Illumina |
FC-121-0202 |
|
TruSight Hereditary Cancer (8 Enrichment Reactions)(optional) |
Illumina |
20029551 |
|
TruSight Cardio (8 Enrichment Reactions)(optional) |
Illumina |
20029229 |
|
TruSeq Neurodegeneration (8 Enrichment Reactions)(optional) |
Illumina |
20029550 |
|
Illumina Custom Enrichment Panel via DesignStudio (8 Enrichment Reactions)(optional) |
Illumina |
20025371 |
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Preset
|
|||
|
PCR Cycles |
Numeric |
||||||
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must Move Forward |
|
Master Step 10: Capture Hybridize Probes (Nextera Flex for Enrichment)
Step Type: Standard
Input = Pooled Pre-Enriched Libraries
Output = Hybridized Probes
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Illumina Exome Panel (8 Enrichment Reactions) (CEX)(optional) |
Illumina |
20020183 |
|
TruSight One (6 Enrichment Reactions) (TOO)(optional) |
Illumina |
20029227 |
|
TruSight One Expanded (6 Enrichment Reactions) (TOE)(optional) |
Illumina |
20029226 |
|
TruSight Cancer (8 Enrichment Reactions)(optional) |
Illumina |
FC-121-0202 |
|
TruSight Hereditary Cancer (8 Enrichment Reactions)(optional) |
Illumina |
20029551 |
|
TruSight Cardio (8 Enrichment Reactions)(optional) |
Illumina |
20029229 |
|
TruSeq Neurodegeneration (8 Enrichment Reactions)(optional) |
Illumina |
20029550 |
|
Illumina Custom Enrichment Panel via DesignStudio (8 Enrichment Reactions)(optional) |
Illumina |
20025371 |
|
Setting |
Value |
||||||
|---|---|---|---|---|---|---|---|
|
Destination Containers |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Total Samples |
Numeric |
Preset
|
||||||
|
EE1 (uL) |
Numeric |
Calculated = Total Samples * 28.5 * 1.1 |
||||||||
|
HP3 (uL) |
Numeric |
Calculated = Total Samples * 1.5 *1.1 |
||||||||
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Total Samples and Calculate Master Mix |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must Move Forward |
|
Master Step 11: Amplify Enriched Library (Nextera Flex for Enrichment)
Step Type: Standard
Input = Pooled Pre-Enriched Libraries
Output = Hybridized Probes
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Illumina Exome Panel (8 Enrichment Reactions) (CEX)(optional) |
Illumina |
20020183 |
|
TruSight One (6 Enrichment Reactions) (TOO)(optional) |
Illumina |
20029227 |
|
TruSight One Expanded (6 Enrichment Reactions) (TOE)(optional) |
Illumina |
20029226 |
|
TruSight Cancer (8 Enrichment Reactions)(optional) |
Illumina |
FC-121-0202 |
|
TruSight Hereditary Cancer (8 Enrichment Reactions)(optional) |
Illumina |
20029551 |
|
TruSight Cardio (8 Enrichment Reactions)(optional) |
Illumina |
20029229 |
|
TruSeq Neurodegeneration (8 Enrichment Reactions)(optional) |
Illumina |
20029550 |
|
Illumina Custom Enrichment Panel via DesignStudio (8 Enrichment Reactions)(optional) |
Illumina |
20025371 |
|
Setting |
Value |
||||||
|---|---|---|---|---|---|---|---|
|
Destination Containers |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Preset
|
|||
|
PCR Cycles |
Numeric |
||||||
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
|
Master Step 11: Clean Up Amplified Enriched Library (Nextera Flex for Enrichment)
Input = Amplified Enriched Libraries
Output = Cleaned up amplified enriched libraries
|
Kit Name |
Supplier |
Cat. # |
|---|---|---|
|
Agencourt AMPure XP beads, 5 ml |
Beckman Coulter |
A63880 |
|
Illumina Exome Panel (8 Enrichment Reactions) (CEX)(optional) |
Illumina |
20020183 |
|
TruSight One (6 Enrichment Reactions) (TOO)(optional) |
Illumina |
20029227 |
|
TruSight One Expanded (6 Enrichment Reactions) (TOE)(optional) |
Illumina |
20029226 |
|
TruSight Cancer (8 Enrichment Reactions)(optional) |
Illumina |
FC-121-0202 |
|
TruSight Hereditary Cancer (8 Enrichment Reactions)(optional) |
Illumina |
20029551 |
|
TruSight Cardio (8 Enrichment Reactions)(optional) |
Illumina |
20029229 |
|
TruSeq Neurodegeneration (8 Enrichment Reactions)(optional) |
Illumina |
20029550 |
|
Illumina Custom Enrichment Panel via DesignStudio (8 Enrichment Reactions)(optional) |
Illumina |
20025371 |
|
Setting |
Value |
||||||
|---|---|---|---|---|---|---|---|
|
Destination Containers |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step Data |
Master Step Fields |
80% EtOH prep Date |
Date |
|
|
Step File Placeholders |
|
File Name |
Log |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
Safe Stopping Point