Generic CSV Parser Template (Python)
Compatibility: API version 2
Many different types of CSV files are attached to BaseSpace Clarity LIMS. This example provides a template for a script that can parse a wide range of simple CSV files into Clarity LIMS. The user can change parameters to read the format of the file to be parsed.
The Lab Instrument Tool Kit includes the parseCSV script, which allows for parsing of CSV files. However, this tool has strict limitations in its strategy for mapping data from the file to corresponding samples in Clarity LIMS. For information on the parseCSV script, refer to the Clarity LIMS Integrations and Tool Kits documentation.
Protocol step configuration
CSV files are attached to a protocol step. Artifact UDFs, where data will be written to, need to be configured for artifacts and for the protocol step.
Parameters
The script accepts the following parameters:
|
-u |
The username of the current user (Required) |
|
-p |
The password of the current user (Required) |
|
-s |
T he URI of the step that launches the script - the {stepURI:v2:http} token (Required) |
An example of the full syntax to invoke the script is as follows:
/usr/bin/python /opt/gls/clarity/customextensions/genericParser.py -u {username} -p {password} -s {stepURI:v2} -r {compoundOutputFileLuid0}
The script contains an area with a number of configurable variables. This allows an FAS or bioinformatician to customize the script to parse their specific file. The following variables within the script are configurable:
|
MAPPING MODE |
What will the script use to map the measurements to the artifacts in LIMS? (see Generic CSV Parser Template (Python) for more detail) |
|
artifactUDFMap |
A Python dictionary where the key is the name of a column in the txt file, and the value is a UDF in Clarity LIMS. (see Generic CSV Parser Template (Python) for more detail) |
|
delim |
How is the file delimited? (ex. ',' for .commas or '\t' for tabs) |
MAPPING MODES
There are many attributes of samples that can be used to map the data in the text file with the corresponding derived samples in Clarity LIMS. The script should be configured such that one of these modes is set to True.
Three modes are available:
|
MapTo_WellLocation |
The data will be associated with the well locations of the output artifacts for the given step. |
|
MapTo_WellLocation |
The data will be associated with the well locations of the output artifacts for the given step. |
|
MapTo_UDFValue |
The data will be associated with the value of a specified UDF of the output artifacts. |
For any of the three modes, a mapping column value must be explicitly given. The value is the index of the column containing the mapping data (either artifact name, well location, or UDF value).
If using the mode MapTo_UDFValue, a UDFName must be given. This is the name of the UDF in clarity which will be used to match the value found in the mapping column.
artifactUDFMap
artifactUDFMap = { "Concentration" : "Concentration", "Avg. Size" : "Average Size"}
This Python dictionary maps the name of columns in the txt file to artifact UDFs for the outputs of the step. The data from these columns in the file will be written to these UDFs for the output artifacts. The dictionary can contain an unlimited number of UDFs. The dictionary keys, (left side), are the names of the columns in the txt file, and the dictionary values, (right side), are the names of the UDFs as configured for the artifacts.
| • | You are running a version of Python that is supported by Clarity LIMS, as documented in the Technical Requirements. |
| • | The attached files are placed on the LIMS server, in the /opt/gls/clarity/customextensions folder. |
| • | The example code is provided for illustrative purposes only. It does not contain sufficient exception handling for use 'as is' in a production environment. |