import sys
import getopt
import xml.dom.minidom
import glsapiutil
from xml.dom.minidom import parseString
HOSTNAME = ""
VERSION = ""
BASE_URI = ""
DEBUG = False
api = None
ARTIFACTS = None
CACHE_IDS = []
I2OMap = {} # A mapping of inputs to their outputs
def setupGlobalsFromURI( uri ):
global HOSTNAME
global VERSION
global BASE_URI
tokens = uri.split( "/" )
HOSTNAME = "/".join(tokens[0:3])
VERSION = tokens[4]
BASE_URI = "/".join(tokens[0:5]) + "/"
if DEBUG is True:
print HOSTNAME
print BASE_URI
def getStepConfiguration( ):
response = ""
if len( args[ "stepURI" ] ) > 0:
stepXML = api.getResourceByURI( args[ "stepURI" ] )
stepDOM = parseString( stepXML )
nodes = stepDOM.getElementsByTagName( "configuration" )
if nodes:
response = nodes[0].toxml()
return response
def cacheArtifact( limsid ):
global CACHE_IDS
if limsid not in CACHE_IDS:
CACHE_IDS.append( limsid )
def prepareCache():
global ARTIFACTS
lXML = ''
for limsid in CACHE_IDS:
link = ''
lXML += link
lXML += ''
mXML = api.getBatchResourceByURI( BASE_URI + "artifacts/batch/retrieve", lXML )
ARTIFACTS = parseString( mXML )
def getArtifact( limsid ):
response = None
elements = ARTIFACTS.getElementsByTagName( "art:artifact" )
for artifact in elements:
climsid = artifact.getAttribute( "limsid" )
if climsid == limsid:
response = artifact
return response
def createContainer( type, name ):
response = ""
if type == '96':
cType = '1'
cTypeName = "96 well plate"
elif type == '384':
cType = '3'
cTypeName = "384 well plate"
xml =''
xml += ''
xml += '' + name + ''
xml += ''
xml += ''
response = api.createObject( xml, BASE_URI + "containers" )
rDOM = parseString( response )
Nodes = rDOM.getElementsByTagName( "con:container" )
if Nodes:
temp = Nodes[0].getAttribute( "limsid" )
response = temp
return response
def autoPlace():
global I2OMap
c96 = createContainer( '96', '96 WP' )
## step one: get the process XML
pURI = BASE_URI + "processes/" + args[ "limsid" ]
pXML = api.getResourceByURI( pURI )
pDOM = parseString( pXML )
IOMaps = pDOM.getElementsByTagName( "input-output-map" )
for IOMap in IOMaps:
output = IOMap.getElementsByTagName( "output" )
oType = output[0].getAttribute( "output-type" )
## switch these lines depending upon whether you are placing ResultFile measurements, or real Analytes
if oType == "Analyte":
##if oType == "ResultFile":
limsid = output[0].getAttribute( "limsid" )
cacheArtifact( limsid )
nodes = IOMap.getElementsByTagName( "input" )
iLimsid = nodes[0].getAttribute( "limsid" )
cacheArtifact( iLimsid )
## create a map entry
if not iLimsid in I2OMap.keys():
I2OMap[ iLimsid ] = []
temp = I2OMap[ iLimsid ]
temp.append( limsid )
I2OMap[ iLimsid ] = temp
## build our cache of Analytes
prepareCache()
pXML = ''
pXML += ( '' )
pXML += ( '' )
pXML += getStepConfiguration()
pXML += ''
pXML += ( '' )
pXML += ''
## let's process our cache, one input at a time
for key in I2OMap:
## get the well position for the input
iDOM = getArtifact( key )
nodes = iDOM.getElementsByTagName( "value" )
iWP = api.getInnerXml( nodes[0].toxml(), "value" )
## well placement should always contain a :
if iWP.find( ":" ) == -1:
print( "WARN: Unable to determine well placement for artifact " + key )
break
outs = I2OMap[ key ]
print( key + str(outs) )
for output in outs:
oDOM = getArtifact( output )
oURI = oDOM.getAttribute( "uri" )
oWP = iWP
plXML = ''
plXML += ( '' )
plXML += ( '' + oWP + '' )
pXML += plXML
pXML += ''
rXML = api.createObject( pXML, args[ "stepURI" ] + "/placements" )
rDOM = parseString( rXML )
nodes = rDOM.getElementsByTagName( "output-placement" )
if nodes:
msg = "Auto-placement of replicates occurred successfully"
api.reportScriptStatus( args[ "stepURI" ], "OK", msg )
else:
msg = "An error occurred trying to auto-place these replicates"
msg = msg + rXML
print msg
api.reportScriptStatus( args[ "stepURI" ], "WARN", msg )
def main():
global api
global args
args = {}
opts, extraparams = getopt.getopt(sys.argv[1:], "l:u:p:s:")
for o,p in opts:
if o == '-l':
args[ "limsid" ] = p
elif o == '-u':
args[ "username" ] = p
elif o == '-p':
args[ "password" ] = p
elif o == '-s':
args[ "stepURI" ] = p
setupGlobalsFromURI( args[ "stepURI" ] )
api = glsapiutil.glsapiutil()
api.setHostname( HOSTNAME )
api.setVersion( VERSION )
api.setup( args[ "username" ], args[ "password" ] )
## at this point, we have the parameters the EPP plugin passed, and we have network plumbing
## so let's get this show on the road!
autoPlace()
if __name__ == "__main__":