Illumina Preset Protocol - GenomeStudio
The GenomeStudio workflow includes the following functionality.
| • | Automatic Generation of a sample sheet for genotyping or methylation. These sample sheets can then be used in GenomeStudio to create a project. |
Protocol 1: Infinium Genotyping Analysis (GenomeStudio)
Protocol Type: Other
Master Step 1: Create Infinium Genotyping Analysis SampleSheet - GenomeStudio
Step Type: No Output
|
Section |
Subsection |
Setting |
Value |
Specification |
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
BeadPool Manifest |
Text |
||||||||||
|
Multiline Text Fields |
Comment |
Multiline Text |
|||||||||||
|
Step File Placeholders |
|
File Name |
GenomeStudio Genotyping Sample Sheet |
Auto |
|||||||||
|
File Generation Log |
Auto |
||||||||||||
|
Log |
Auto |
||||||||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
Text |
|
|||||||||
|
BeadChip Barcode |
Text |
|
|||||||||||
|
BeadChip Position |
Text |
|
|||||||||||
|
DNA Plate Barcode |
Text |
|
|||||||||||
|
Sample_Well |
Text |
|
|||||||||||
|
Array Secondary Analysis |
Text |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Generate GenomeStudio Genotyping Sample Sheet |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual |
||
|
Command line
|
|||
|
Set Next Step - Remove |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
Mark Protocol Complete
Protocol 2: Infinium Methylation Analysis (GenomeStudio)
Protocol Type: Other
Master Step 1: Create Infinium Methylation Analysis SampleSheet - GenomeStudio
Step Type: No Output
|
Section |
Subsection |
Setting |
Value |
Specification |
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Comment |
Multiline Text |
||||||||||
|
Step File Placeholders |
|
File Name |
GenomeStudio Methylation Sample Sheet |
Auto |
|||||||||
|
File Generation Log |
Auto |
||||||||||||
|
Log |
Auto |
||||||||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
Text |
|
|||||||||
|
BeadChip Barcode |
Text |
|
|||||||||||
|
BeadChip Position |
Text |
|
|||||||||||
|
DNA Plate Barcode |
Text |
|
|||||||||||
|
Sample_Well |
Text |
|
|||||||||||
|
Array Secondary Analysis |
Text |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Generate GenomeStudio Genotyping Sample Sheet |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual |
||
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
|
Mark Protocol Complete