Illumina Preset Protocol - Infinium HTS Assay Manual
The Infinium HTS Assay Manual workflow includes the following functionality.
| • | Preconfigured Infinium HTS Assay Manual protocols. |
| • | Automatic placement of samples when necessary. |
| • | Automatic step transition when required. |
| • | Automatic calculation or display of reagents at every step in the protocol. |
Protocol 1: Prep Sample (Infinium HTS Assay Manual)
Protocol Type: Sample Prep
Master Step 1: Select Infinium Kit-Infinium HTS
Step Type: No Output
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
HTS Infinium Kits |
Text Dropdown |
Default list of HTS Infinium kits |
||||||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Infinium HTS Kit Name |
Trigger Location |
Step |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|||
|
Set Next Step |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
|
|
Setting |
Value |
||||||
|---|---|---|---|---|---|---|---|
|
Start Next Step |
Manual |
||||||
|
Assign Next Step |
Manual |
||||||
|
Must Move Forward |
Optional:
|
Master Step 2: Quantify DNA-Infinium PicoGreen
Step Type: Standard QC
|
Kit Name |
Supplier |
|---|---|
|
1X TE |
|
|
Lambda DNA |
|
|
PicoGreen dsDNA quantification reagent |
|
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Stock Lambda DNA (ng/µl) |
Numeric |
||||||||||||||||
|
Stock Lambda DNA for A1 (µl) |
Numeric |
Calculated - (233.3 * 75)/Stock Lambda DNA (ng/µl) |
|||||||||||||||||
|
1X TE for A1 (µl) |
Numeric |
Calculated - 233.3 - Stock Lambda DNA for A1 (µl) |
|||||||||||||||||
|
No. of QDNA Plates |
Numeric Dropdown |
1,2,3 |
|||||||||||||||||
|
PicoGreen (µl) |
Numeric |
Calculated - If No. of QDNA Plates = 1 then 115; if No. of QDNA Plates = 2 then 215; if No. of QDNA Plates = 3 then 315 |
|||||||||||||||||
|
1X TE (ml) |
Numeric |
Calculated - If No. of QDNA Plates = 1 then 23; if No. of QDNA Plates = 2 then 43; if No. of QDNA Plates = 3 then 63 |
|||||||||||||||||
|
Step Data |
Multiline Text Fields |
Lambda serial dilution instruction notes |
Multiline Text |
Default Read Only
|
|||||||||||||||
|
Standard QDNA Plate instruction notes |
Multiline Text |
Default Read Only
|
|||||||||||||||||
|
Sample QDNA Plate instruction notes |
Multiline Text |
Default Read Only
|
|||||||||||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
||||||||||||||||
|
File Name |
PicoGreen Results File |
Manual |
|||||||||||||||||
|
Sample Table |
Table Columns |
LIMS ID Sample Name Container Name Well Project Name |
Defaults |
||||||||||||||||
|
Infinium Kit Name |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Calculate Stock Lambda DNA and PicoGreen Dilution |
Trigger Location |
Record Details |
|
|
Trigger Style |
Manual button |
|
|
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
Master Step 3: Amplify DNA-Infinium HTS
Step Type: Standard
|
Kit Name |
Supplier |
|---|---|
|
MA1 - Infinium |
Illumina |
|
MA2 - Infinium |
Illumina |
|
MSM - Infinium |
Illumina |
|
NaOH |
|
|
Setting |
Value |
|---|---|
|
Destination Containers |
96 well plate |
|
Well Sort Order |
Column |
|
Placement Pattern |
Same Shape |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
HTS Instruction Notes |
Multiline Text |
Default Read Only
|
||||||||||||||||||
|
Comment |
Multiline Text |
|||||||||||||||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||||||||||||||
|
Sample Table |
Table Columns |
LIMS ID Sample Name Container Name Well Project Name |
Defaults |
|||||||||||||||||||
|
Infinium Kit Name |
|
|||||||||||||||||||||
|
DNA Plate Barcode |
|
|
Automation Name |
Setting |
Value |
Specification |
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Validate MSA3 Plate Barcode and Set Sample Placement Information |
Trigger Location |
Placement |
||||||||||
|
Trigger Style |
Automatic upon exit |
|
||||||||||
|
Command line
|
||||||||||||
|
Calculation Regular expression for MSA3 barcode 2 letters, 7 number - MSA3. Saves for future use:
|
||||||||||||
|
Copy Infinium Kit Name |
Trigger Location |
Record Details |
||||||||||
|
Trigger Style |
Automatic upon entry |
|
||||||||||
|
Command line
|
||||||||||||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|||||||||
|
Trigger Style |
Automatic upon exit |
|
||||||||||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must Move Forward |
Master Step 4: Incubate DNA-Infinium
Step Type: No Outputs
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Instruction Notes |
Multiline Text |
Default
|
||||||||||||
|
Comment |
Multiline Text |
|||||||||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
|
|||||||||||||
|
|
DNA Plate Barcode |
|
||||||||||||||
|
|
Sample_Plate |
|
||||||||||||||
|
|
Sample_Well |
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
Master Step 5: Fragment DNA-Infinium
Step Type: No Outputs
|
Kit Name |
Supplier |
|---|---|
|
FMS - Infinium |
Illumina |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Instruction Notes |
Multiline Text |
Default
|
||||||
|
Comment |
Multiline Text |
|||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
Global field - derived sample |
|||||||
|
DNA Plate Barcode |
Global field - derived sample |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
Master Step 6: Precipitate DNA-Infinium
Step Type: No Outputs
|
Kit Name |
Supplier |
|---|---|
|
PM1-Infinium |
Illumina |
|
100% 2-propanol |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Blue Pellet Presence |
Checkbox |
|||||||
|
100% 2-propanol Prep Date |
Date Selection |
|||||||||
|
|
Multiline Text Fields |
Instruction notes |
Multiline Text |
Default
|
||||||
|
Comment |
Multiline Text |
|||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||
|
Sample Table |
Table Columns |
Infinium Kit Name |
Global field - derived sample |
|||||||
|
DNA Plate Barcode |
Global field - derived sample |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
Master Step 7: Resuspend DNA-Infinium
Step Type: No Outputs
|
Kit Name |
Supplier |
|---|---|
|
RA1-Infinium |
Illumina |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Instruction Notes (HTS) |
Multiline Text |
Default
|
|||
|
Comment |
Multiline Text |
||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
||||
|
Sample Table |
Table Columns |
Infinium Kit Information |
Global field - derived sample |
||||
|
DNA Plate Barcode |
Global field - derived sample |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Manual |
|
Assign Next Step |
Automatic |
|
Safe Stopping Point |
Protocol 2: BeadChip Processing (Infinium HTS Assay Manual)
Protocol Type: Sample Prep, Other
Master Step 1: Hybridize DNA to BeadChip - Infinium
Step Type: Standard
|
Kit Name |
Supplier |
|---|---|
|
PB2-Infinium |
Illumina |
|
XC4-Infinium |
Illumina |
|
Setting |
Value |
Specification |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Destination Containers |
|
|
||||||||||||
|
Well Sort Order |
Row |
Configured on master step |
||||||||||||
|
Placement Pattern |
Row |
Configured on master step |
||||||||||||
|
Placement Screen |
|
Configured on step |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Instruction Notes |
Multiline Text |
Default
|
|||
|
Comment |
Multiline Text |
||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|
Automation Name |
Setting |
Value |
Specification |
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Copy Sample Information |
Trigger Location |
Record Details |
||||||||||||||||
|
Trigger Style |
Automatic upon entry |
|
||||||||||||||||
|
Command line
|
||||||||||||||||||
|
Copies over the derived sample information from previous step for use in future step.
|
||||||||||||||||||
|
Generate Sample Placement for InfiniumBeadChip |
Trigger Location |
Placement |
||||||||||||||||
|
Trigger Style |
Automatic upon entry |
|
||||||||||||||||
|
Command line
|
||||||||||||||||||
|
Generates the auto-placement of the samples from the plate to the BeadChip using a PlacementHelper java script and placement pattern file. The placement pattern file describes exactly how the 96 samples map to the BeadChip. Placement pattern file must be named Hybrid Pattern_96_well plate_[container type for the Beadchip].csv. |
||||||||||||||||||
|
Validate BeadChip Barcodes |
Trigger Location |
Placement |
||||||||||||||||
|
Trigger Style |
Automatic upon exit |
|
||||||||||||||||
|
Command line
|
||||||||||||||||||
|
Checks for uniqueness of the barcode and possibly for the actual barcode. |
||||||||||||||||||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
||||||||||||||||
|
Trigger Style |
Automatic upon exit |
|
||||||||||||||||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must Move Forward |
Master Step 2: Wash BeadChips-Infinium
Step Type: No Outputs
|
Kit Name |
Supplier |
|---|---|
|
PB1-Infinium |
Illumina |
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Multiline Text Fields |
Instruction Notes |
Multiline Text |
Default
|
|||
|
Comment |
Multiline Text |
||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
||
|
Command line
|
|
Setting |
Value |
|---|---|
|
Start Next Step |
Automatic |
|
Assign Next Step |
Automatic |
|
Must Move Forward |
Master Step 3: Extend and Stain BeadChip- Infinium
Step Type: No Outputs
|
Kit Name |
Supplier |
|---|---|
|
ATM-Infinium |
Illumina |
|
PB1-Infinium |
Illumina |
|
SML-Infinium |
Illumina |
|
LX1-Infinium |
Illumina |
|
LX2-Infinium |
Illumina |
|
XC3-Infinium |
Illumina |
|
XC4-Infinium |
Illumina |
|
EML-Infinium |
Illumina |
|
RA1-Infinium |
Illumina |
|
70% EtOH |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
EDTA Prep Date |
Date Selector |
|||||||||||||||||||||||||||||||||||||||||||
|
20% EthOH Prep Data |
Date Selector |
|||||||||||||||||||||||||||||||||||||||||||||
|
|
Multiline Text Fields |
Extend Instruction Notes |
Multiline Text |
Default Without allowing pipette tips to touch BeadChip surfaces, fill the reservoir of each flow-through chamber as follows:
|
||||||||||||||||||||||||||||||||||||||||||
|
Stain Instruction Notes |
Multiline Text |
Default Fill the reservoir of each flow-through chamber as follows:
|
||||||||||||||||||||||||||||||||||||||||||||
|
Wash and Coat BeadChips Instruction Notes |
Multiline Text |
Default
|
||||||||||||||||||||||||||||||||||||||||||||
|
Step File Placeholders |
File Name |
Log |
Auto |
|||||||||||||||||||||||||||||||||||||||||||
|
Sample Table |
Table Columns |
Array Instrument |
||||||||||||||||||||||||||||||||||||||||||||
|
Infinium Kit Name |
||||||||||||||||||||||||||||||||||||||||||||||
|
DNA Plate Barcode |
||||||||||||||||||||||||||||||||||||||||||||||
|
BeadChip Barcode |
||||||||||||||||||||||||||||||||||||||||||||||
|
BeadChip Position |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Set Array Instrument |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon entry |
|
|
|
Command line
|
|||
|
Needed because the default setting is not always honored. |
|||
|
Routing Script -iScan |
Trigger Location |
Step |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
|||
|
Set Next Step - Advance |
Trigger Location |
Record Details |
|
|
Trigger Style |
Automatic upon exit |
|
|
|
Command line
|
End of Workflow