Illumina Preset Protocol - Nextera XT
The Nextera XT includes the following functionality:
| • | Preconfigured Nextera XT protocol that converts the mRNA in total RNA into a library of template molecules of known strand origin. The library is suitable for subsequent cluster generation and DNA sequencing. |
| • | Automated calculation of sample and buffer volumes. |
| • | Automated calculation or display of reagents at every step in the protocol. |
| • | Automatic step transition when required. |
| • | Automatic placement of samples when necessary. |
| • | Automated assignment of QC Pass/Fail, based on user-selected threshold values. |
| • | A routing script that allows sequencing of libraries using any Illumina sequencing instrument. |
Protocol 1: Nextera XT DNA
Master Step 1: Tagment
Step Type:
Input = gDNA
Output = Tagmented and neutralized gDNA
SharedResultFile = Log File
|
Kit Name |
Supplier |
|---|---|
|
Nextera XT DNA Library Prep Kit, Box 1 (FC-131-1096) ATM |
|
|
Nextera XT DNA Library Prep Kit, Box 2 (FC-131-1096) NT |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Group of Defaults
|
||||||
|
Multiline Text Fields |
Comment |
Multiline Text |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Normalize gDNA (Nextera XT) |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Next Step = Set Next Step - Advance |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
Master Step 2: Amplification
(This is the Drop-down text)
Input = Tagmented and neutralized gDNA
Output = Library DNA
SharedResultFile = Log File
Place Samples = Autoplacement into 96 well plate
|
Kit Name |
Supplier |
|---|---|
|
Nextera XT DNA Library Prep Kit, Box 1 (FC-131-1096) |
|
|
NPM |
|
Setting |
Value |
|---|---|
|
Label Groups (for 5.x) |
Nextera XT v2 Full Set.xlsx |
|
Nextera XT v2 Set A.xlsx |
|
|
Nextera XT v2 Set B.xlsx |
|
|
Nextera XT v2 Set C.xlsx |
|
|
Nextera XT v2 Set D.xlsx |
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Thermal Cycler Program |
Text |
Group of Defaults
|
||||||
|
Multiline Text Fields |
Comment |
Multiline Text |
||||||||
|
Step File Placeholders |
|
File Name |
Log |
Auto |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Step = Set Next Step - Advance |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
Master Step 3: Clean Up
Input = Amplified Libraries
Output = Purified DNA Libraries
SharedResultFile = Log File
Place Samples = Auto placement into 96 well plate
|
Kit Name |
Supplier |
|---|---|
|
AMPure XP beads |
|
|
Nextera XT DNA Library Prep Kit, Box 1 (FC-131-1096) |
|
Section |
Subsection |
Setting |
Value |
Specification |
|---|---|---|---|---|
|
Step Data |
Master Step Fields |
80% EtOH Prep Date |
Date |
|
|
Multiline Text Fields |
Comment |
Multiline Text |
||
|
Step File Placeholders |
|
File Name |
Log |
Auto |
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Next Step = Set Next Step - Advance |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
Master Step 4: Bioanalyzer QC (Library Validation)
Input = Purified DNA Libraries
Output = Result File
SharedResultFile =
|
Section |
Subsection |
Setting |
Value |
Specification |
|||
|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
Criteria 1 - Source Data Field |
Preset
|
||||
|
Criteria 1 - Operator |
Preset
|
||||||
|
Criteria 1 - Threshold Value |
Preset
|
||||||
|
Criteria 2 - Source Data Field |
Preset
|
||||||
|
Criteria 2 - Operator |
Preset
|
||||||
|
Criteria 2 - Threshold Value |
Preset
|
||||||
|
BA Instrument |
Preset
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Parse Bioanalyzer XML and assign QC flags |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Set Next Step - Output PASS/FAIL |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
Master Step 5: Normalize Libraries
Input = Purified DNA Libraries
Output = Normalized Libraries
SharedResultFile = Log File
Place Samples = Automatic placement into 96 well plate
|
Kit Name |
Supplier |
|---|---|
|
Nextera XT DNA Library Prep Kit, Box 1 (FC-131-1096) |
|
|
Nextera XT DNA Library Prep Kit, Box 2 (FC-131-1096) |
|
|
Section |
Subsection |
Setting |
Value |
Specification |
||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Step Data |
Master Step Fields |
0.1 N NaOH Prep Date |
Date |
|||||||||||||||||||
|
Multiline Text Fields |
Comment |
Multiline Text |
||||||||||||||||||||
|
Step File Placeholders |
|
File Name |
Log |
Auto |
||||||||||||||||||
|
Sample Table |
Table Columns |
Normalized Molarity (nM) |
Numeric |
Required |
||||||||||||||||||
|
Sequencing Instrument |
Text |
Preset Required
|
|
Automation Name |
Setting |
Value |
Specification |
|---|---|---|---|
|
Next Step = Set Next Step - Remove |
Trigger Location |
||
|
Trigger Style |
|||
|
Command line
|
|||
|
Finish Step = Routing script - Normalize Libraries |
Trigger Location |
||
|