Block List
The following table lists the genes that have associated block listed sites. For the exact location of the block listed site, contact Illumina Technical Support.
Gene |
Number of Block List Sites |
Gene |
Number of Block List Sites |
Gene |
Number of Block List Sites |
---|---|---|---|---|---|
ABL1 |
5 |
FGFR2 |
144 |
PAX7 |
5 |
AKT2 |
5 |
FGFR3 |
1 |
PAX8 |
275 |
AKT3 |
20 |
FGFR4 |
36 |
PBRM1 |
3 |
ALK |
90 |
FLCN |
2 |
PDCD1 |
2 |
ANKRD11 |
6 |
FLI1 |
36 |
PDGFRA |
5 |
ANKRD26 |
9 |
FLT1 |
91 |
PDGFRB |
2 |
AR |
81 |
FLT4 |
3 |
PDK1 |
1 |
ARID1A |
40 |
FOXA1 |
48 |
PDPK1 |
6 |
ARID1B |
87 |
FOXL2 |
4 |
PGR |
5 |
ARID2 |
1 |
FOXO1 |
2 |
PHF6 |
2 |
ASXL1 |
3 |
FOXP1 |
3 |
PHOX2B |
15 |
ASXL2 |
5 |
FUBP1 |
1 |
PIK3C2G |
2 |
ATM |
2 |
GATA4 |
6 |
PIK3CA |
18 |
ATR |
3 |
GATA6 |
12 |
PIK3CB |
42 |
ATRX |
17 |
GEN1 |
1 |
PIK3R1 |
6 |
AURKA |
1 |
GID4 |
3 |
PIK3R2 |
2 |
AXIN2 |
4 |
GNAQ |
4 |
PLCG2 |
3 |
AXL |
74 |
GNAS |
11 |
PLK2 |
2 |
BBC3 |
2 |
GPR124 |
3 |
PMAIP1 |
7 |
BCL10 |
2 |
GRM3 |
1 |
PMS2 |
1 |
BCL2L11 |
16 |
H3F3A |
1 |
POLE |
3 |
BCOR |
2 |
H3F3C |
2 |
PPARG |
446 |
BCORL1 |
1 |
HGF |
1 |
PRDM1 |
1 |
BCR |
64 |
HIST1H1C |
2 |
PRKCI |
2 |
BIRC3 |
1 |
HLA-A |
72 |
PRKDC |
5 |
BLM |
4 |
HNF1A |
2 |
PTCH1 |
13 |
BMPR1A |
4 |
HNRNPK |
9 |
PTEN |
41 |
BRAF |
283 |
HOXB13 |
1 |
PTPRS |
14 |
BRCA1 |
49 |
HSP90AA1 |
4 |
PTPRT |
2 |
BRCA2 |
21 |
ICOSLG |
6 |
QKI |
2 |
BRD4 |
16 |
IFNGR1 |
2 |
RAD21 |
1 |
CARD11 |
4 |
iIndel |
91 |
RAD50 |
5 |
CASP8 |
2 |
INHBA |
4 |
RAD51 |
18 |
CBL |
8 |
INPP4A |
1 |
RAD51B |
8 |
CCND1 |
25 |
INPP4B |
1 |
RAF1 |
98 |
CCND3 |
49 |
IRS1 |
9 |
RANBP2 |
12 |
CCNE1 |
72 |
IRS2 |
19 |
RARA |
2 |
CD74 |
50 |
iSNP |
4 |
RASA1 |
1 |
CDH1 |
4 |
JAK2 |
4 |
RB1 |
5 |
CDK12 |
3 |
JUN |
7 |
RBM10 |
13 |
CDK4 |
46 |
KAT6A |
5 |
RECQL4 |
3 |
CDK6 |
13 |
KDM5A |
7 |
REL |
3 |
CDK8 |
4 |
KDM5C |
2 |
RET |
3 |
CDKN2B |
2 |
KDM6A |
2 |
RFWD2 |
22 |
CEBPA |
12 |
KDR |
1 |
RICTOR |
1 |
CHD2 |
5 |
KIF5B |
7 |
ROS1 |
287 |
CHD4 |
12 |
KIT |
5 |
RPS6KA4 |
3 |
CHEK1 |
75 |
KMT2B |
51 |
RPS6KB1 |
109 |
CHEK2 |
64 |
KMT2C |
118 |
RUNX1 |
3 |
chrY |
93 |
KMT2D |
108 |
SDHA |
18 |
CIC |
2 |
KRAS |
44 |
SDHB |
3 |
CREBBP |
4 |
LAMP1 |
64 |
SDHD |
17 |
CSNK1A1 |
4 |
LATS1 |
1 |
SETBP1 |
7 |
CTNNB1 |
1 |
LATS2 |
4 |
SETD2 |
26 |
CUL3 |
1 |
LoH |
85 |
SF3B1 |
1 |
CUX1 |
9 |
LRP1B |
3 |
SH2B3 |
4 |
DAXX |
5 |
LZTR1 |
1 |
SH2D1A |
2 |
DDR2 |
1 |
MAGI2 |
2 |
SLIT2 |
1 |
DDX41 |
1 |
MALT1 |
4 |
SLX4 |
2 |
DIS3 |
2 |
MAP2K2 |
1 |
SMARCA4 |
4 |
DNAJB1 |
6 |
MAP2K4 |
5 |
SMC1A |
1 |
DNMT1 |
1 |
MAP3K1 |
8 |
SMC3 |
8 |
DNMT3A |
4 |
MAP3K14 |
2 |
SMO |
2 |
DOT1L |
2 |
MAP3K4 |
10 |
SOX10 |
7 |
E2F3 |
70 |
MAPK1 |
6 |
SOX17 |
1 |
EGFR |
304 |
MAPK3 |
6 |
SOX9 |
14 |
EIF4E |
12 |
MCL1 |
1 |
SPEN |
4 |
EML4 |
9 |
MDC1 |
23 |
STAG1 |
5 |
EP300 |
1 |
MDM2 |
53 |
STAG2 |
2 |
ERBB2 |
14 |
MDM4 |
67 |
STAT4 |
1 |
ERBB3 |
62 |
MED12 |
28 |
STAT5A |
1 |
ERCC1 |
53 |
MGA |
6 |
STAT5B |
4 |
ERCC2 |
57 |
MLL |
9 |
SUFU |
5 |
ERCC3 |
4 |
MLLT3 |
18 |
SUZ12 |
9 |
ERCC5 |
4 |
MRE11A |
5 |
TAF1 |
9 |
ERG |
2 |
MSH3 |
10 |
TBX3 |
1 |
ESR1 |
32 |
MSH6 |
2 |
TCEB1 |
1 |
ETS1 |
45 |
MSI |
148 |
TCF3 |
2 |
ETV1 |
862 |
MST1 |
18 |
TCF7L2 |
6 |
ETV4 |
502 |
MYB |
402 |
TERT |
2 |
ETV5 |
11 |
MYC |
78 |
TET1 |
1 |
ETV6 |
187 |
MYCL1 |
28 |
TET2 |
23 |
EWSR1 |
364 |
MYCN |
69 |
TFE3 |
299 |
EZH2 |
2 |
MYOD1 |
3 |
TFRC |
33 |
FANCA |
1 |
NAB2 |
10 |
TGFBR1 |
6 |
FANCD2 |
11 |
NCOA3 |
28 |
TGFBR2 |
2 |
FANCG |
10 |
NCOR1 |
9 |
TMEM127 |
5 |
FANCI |
1 |
NF1 |
3 |
TMPRSS2 |
236 |
FANCL |
1 |
NKX2-1 |
4 |
TOP2A |
1 |
FAT1 |
2 |
NOTCH1 |
4 |
TP53 |
22 |
FBXW7 |
4 |
NOTCH3 |
7 |
TRAF7 |
4 |
FGF1 |
25 |
NOTCH4 |
9 |
TSC1 |
4 |
FGF10 |
17 |
NPM1 |
5 |
TSC2 |
1 |
FGF14 |
15 |
NRAS |
29 |
U2AF1 |
1 |
FGF19 |
102 |
NRG1 |
47 |
VEGFA |
7 |
FGF2 |
26 |
NTRK1 |
134 |
WISP3 |
2 |
FGF23 |
38 |
NTRK2 |
145 |
WT1 |
10 |
FGF3 |
60 |
NTRK3 |
13 |
XIAP |
1 |
FGF4 |
25 |
NUTM1 |
134 |
XPO1 |
2 |
FGF5 |
14 |
PAK1 |
68 |
XRCC2 |
1 |
FGF6 |
9 |
PAK3 |
8 |
YAP1 |
1 |
FGF7 |
9 |
PALB2 |
1 |
ZBTB7A |
11 |
FGF8 |
30 |
PARK2 |
23 |
ZFHX3 |
56 |
FGF9 |
21 |
PARP1 |
2 |
ZNF703 |
7 |
FGFR1 |
26 |
PAX3 |
156 |
ZRSR2 |
2 |