Additional Sample Sheet Fields for Autolaunch
Autolaunch-compatible sample sheets contain the following fields specific to autolaunch configuration. For more information on DRAGEN TSO 500 sample sheet requirements, refer to DRAGEN TruSight Oncology 500 Analysis v2.1.1 (Local) User Guide (Document # 200019138).
Parameter | Details | Required | ||||||||||||||||||||||||
|
Cloud_TSO500 |
||||||||||||||||||||||||||
|
Sample_ID |
The unique ID to identify a sample. The sample ID is included in the output file names. Sample IDs are not case sensitive. Sample IDs must have the following characteristics:
|
Yes |
||||||||||||||||||||||||
|
Index_ID |
The index ID used for the sample. Must be unique per sample unless samples are assigned different lanes. Mismatches between the samples and index primers can cause incorrect result reporting due to loss of positive sample identification. Enter sample IDs and assign indexes in the sample sheet before beginning library preparation. Valid indexes for DNA samples are:
Valid Indexes for RNA Samples are:
|
Yes |
||||||||||||||||||||||||
|
Sample_Type |
Enter DNA |
Yes |
||||||||||||||||||||||||
|
Pair_ID |
A unique ID that links DNA and RNA from the same biological sample from the same individual. PairID shares, at most, one DNA and one RNA sample per run. eg, if a Sample_ID is TestSample1-DNA for DNA and TestSample1-RNA for RNA, the Pair_ID TestSample1 will link these samples that are on different rows in the sample sheet together. If the pair ID is associated with more than one DNA or RNA sample, the analysis fails. |
Yes |
||||||||||||||||||||||||
|
Sample_Feature |
For DNA samples that have undergone HRD enrichment, enter HRD in this column of the sample sheet. If the sample has not undergone HRD enrichment, leave the field empty. |
Only required for HRD-enriched samples. |
||||||||||||||||||||||||
|
Sample_Description |
Must meet the following requirements:
|
No |
||||||||||||||||||||||||
|
Cloud_TSO500 |
||||||||||||||||||||||||||
|
SoftwareVersion |
The TSO500 |
No |
||||||||||||||||||||||||
|
StartsFromFastq |
Set the value to TRUE or FALSE. If autolaunching from BCL files, this must be set to FALSE. |
Yes |
||||||||||||||||||||||||
|
Cloud_Data |
||||||||||||||||||||||||||
|
Sample_ID |
The same sample ID used in the Cloud_TSO500S_Data section. |
No |
||||||||||||||||||||||||
|
ProjectName |
The BaseSpace project name. |
No |
||||||||||||||||||||||||
|
LibraryName |
Combination of sample ID and index values in the following format: sampleID_Index_Index2. |
No |
||||||||||||||||||||||||
|
LibraryPrepKitName |
The Library Prep Kit used. |
No |
||||||||||||||||||||||||
|
IndexAdapterKitName |
The Index Adapter Kit used. |
No |
||||||||||||||||||||||||
|
Cloud_Settings |
||||||||||||||||||||||||||
|
GeneratedVersion |
The cloud GSS version used to create the sample sheet. Optional if manually updating a sample sheet. |
No |
||||||||||||||||||||||||
|
CloudWorkflow |
Ica_workflow_1 |
Yes |
||||||||||||||||||||||||
|
Cloud_TSO500_Pipeline |
This value is a universal record number (URN). The valid value
|
Yes |
||||||||||||||||||||||||
|
BCLConvert_Pipeline |
The value is a URN in the following format: urn:ilmn:ica:pipeline:<pipeline-ID>#<pipeline-name> |
No |
||||||||||||||||||||||||
