Normalization Options

These options control the preconditioning of the panel of normals and the normalization of the case sample.

Option

Description

--cnv-enable-self-normalization

Enable/disable self-normalization mode, which does not require a panel of normals.

--cnv-extreme-percentile

Specifies the extreme median percentile value at which to filter out samples. The default is 2.5.

--cnv-input

Specifies a target counts file for the case sample under analysis when using a panel of normals.

--cnv-normals-file

Specifies a target.counts.gz file to be used in the panel of normals. You can use this option multiple times, one time for each file.

--cnv-normals-list

Specifies a text file that contains paths to the list of reference target counts files to be used as a panel of normals. Absolute paths are recommended in case the workflow is used later or shared with other users. Relative paths are supported if the paths are relative to the current working directory.

--cnv-max-percent-zero-samples

Specifies the number of zero coverage samples allowed for a target. If the target exceeds the specified threshold, then the target is filtered out. The default value is 5%. The option is sensitive to the number of normal samples being used. Make sure you adjust the threshold accordingly. If your panel of normals size is small and the threshold not adjusted, the option could filter out targets that were not intended to be.

--cnv-max-percent-zero-targets

Specifies the number of zero coverage targets allowed for a sample. If sample exceeds the specified threshold, then the sample is filtered out. The default value is 2.5%. The option is sensitive to the total number of target intervals. Make sure you adjust the threshold accordingly. If the capture kit has a small number of probes and the threshold not adjusted, the option could filter out targets that were not intended to be.

--cnv-target-factor-threshold

Specifies the bottom percentile of panel of normals medians to filter out useable targets. The default is 1% for whole genome processing and 5% for targeted sequencing processing.

--cnv-truncate-threshold

Specifies a percentage threshold for truncating extreme outliers. The default is 0.1%.