Input Files
In addition to the standard input files (reads from FASTQ or BAM, reference genome, etc.), DRAGEN can also take a gene annotations file as input. A gene annotations file aids in the alignment of reads to known splice junctions, and is required for gene expression quantification and gene fusion calling.
To specify a gene annotation file, use the -a (--annotation-file) command line option. The input file must conform to the GTF/GFF specification. See GFF/GTF File Format for more information. The file must contain features of type exon, and the record must contain attributes of type gene_id and transcript_id. An example of a valid GTF file is shown below.
chr1 HAVANA transcript 11869 14409 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000456328.2; ...
chr1 HAVANA exon 11869 12227 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000456328.2; ...
chr1 HAVANA exon 12613 12721 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000456328.2; ...
chr1 HAVANA exon 13221 14409 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000456328.2; ...
chr1 ENSEMBL transcript 11872 14412 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000515242.2; ...
chr1 ENSEMBL exon 11872 12227 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000515242.2; ...
chr1 ENSEMBL exon 12613 12721 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000515242.2; ...
chr1 ENSEMBL exon 13225 14412 . + . gene_id "ENSG00000223972.4"; transcript_id ENST00000515242.2; ...
...
Similarly, a GFF file can be used. Each exon feature must have as a Parent a transcript identifier that is used to group exons. An example of a valid GFF file is shown below.
1 ensembl_havana processed_transcript 11869 14409 . + . ID=transcript:ENST00000456328;
1 havana exon 11869 12227 . + . Parent=transcript:ENST00000456328; ...
1 havana exon 12613 12721 . + . Parent=transcript:ENST00000456328; ...
1 havana exon 13221 14409 . + . Parent=transcript:ENST00000456328; ...
...
In order to distinguish exons within the PAR region of chromosome X from within the PAR region of chromosome Y, the gene_id attribute of all exons of the same gene must be distinct between the two chromosomes. Often case, the gene_id of all exons of a transcript from geneA is equal to gene_id=geneA in chromosome X, and gene_id=geneA_PAR_Y in chromosome Y. It allows the GTF/GFF parser and downstream components to discriminate data associated with PAR genes in chromosome X from data associated with the same PAR genes in chromosome Y.
The DRAGEN host software parses the file for exons within the transcripts and produces splice junctions. The following output displays the number of splice junctions detected.
==================================================================
Generating annotated splice junctions
==================================================================
Input annotations file: ./gencode.v19.annotation.gtf
Splice junctions database file: output/rna.sjdb.annotations.out.tab
Number of genes: 27459
Number of transcripts: 196520
Number of exons: 1196293
Number of splice junctions: 343856
The splice junctions that are detected from the annotation file are also written to *.sjdb.annotations.out.tab. Splice junctions below a minimum length are excluded, which helps filter annotation artifacts that do not meet the minimum required length. This helps to lower the false detection rate for falsely annotated junctions. This minimum annotation splice junction length is controlled by the --rna-ann-sj-min-len option, which has a default value of 6.
Instead of using a GTF file for annotated splice junctions, the DRAGEN software is also capable of reading in an SJ.out.tab file (see SJ.out.tab). This file enables DRAGEN to run in a two-pass mode, where the splice junctions discovered in the first pass (output as SJ.out.tab file) are used to guide the mapping and alignment reads during a second run through DRAGEN. This mode of operation is useful to increase sensitivity for spliced alignments in cases when a gene annotations file is not readily available for the target genome. If a well curated GTF is already available for your target genome, then there is no need to run a second pass with the SJ.out.tab.
Depending on the characteristics of the input file (for example, read depth and distribution) the second pass using the first pass SJ.out.tab may take longer than the first pass.
Components downstream of aligner like gene expression quantification, gene fusion detection and RNA variant calling require GTF file as the input annotations file and are NOT compatible with two-pass splice-junction alignment mode.